| dc.contributor | Department of Building Environment and Energy Engineering | en_US |
| dc.creator | Huang, J | en_US |
| dc.creator | Yu, J | en_US |
| dc.creator | Yang, H | en_US |
| dc.date.accessioned | 2023-11-17T02:58:33Z | - |
| dc.date.available | 2023-11-17T02:58:33Z | - |
| dc.identifier.issn | 0306-2619 | en_US |
| dc.identifier.uri | http://hdl.handle.net/10397/102905 | - |
| dc.language.iso | en | en_US |
| dc.publisher | Pergamon Press | en_US |
| dc.rights | © 2018 Elsevier Ltd. All rights reserved. | en_US |
| dc.rights | © 2018. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/. | en_US |
| dc.rights | The following publication Huang, J., Yu, J., & Yang, H. (2018). Effects of key factors on the heat insulation performance of a hollow block ventilated wall. Applied Energy, 232, 409-423 is available at https://doi.org/10.1016/j.apenergy.2018.09.215. | en_US |
| dc.subject | Energy saving | en_US |
| dc.subject | Frequency-domain finite-difference | en_US |
| dc.subject | Heat transfer | en_US |
| dc.subject | Hollow block ventilated wall | en_US |
| dc.subject | Thermal comfort | en_US |
| dc.subject | Thermal insulation | en_US |
| dc.title | Effects of key factors on the heat insulation performance of a hollow block ventilated wall | en_US |
| dc.type | Journal/Magazine Article | en_US |
| dc.identifier.spage | 409 | en_US |
| dc.identifier.epage | 423 | en_US |
| dc.identifier.volume | 232 | en_US |
| dc.identifier.doi | 10.1016/j.apenergy.2018.09.215 | en_US |
| dcterms.abstract | A hollow block ventilated wall can be cooled down in the summer and warmed in the winter by utilizing the air that flows through cavities. The heat transferred between the outdoor and indoor environments can also be removed. However, neither simulations nor experimental studies on the hollow block ventilated wall have been complete, and factors that affect the thermal insulation performance of hollow block ventilated walls need to be identified. In this paper, the frequency-domain finite-difference method and the Number of Transfer Units method are adopted to build the coupled three-dimensional heat transfer model for investigating the temperature distribution on wall surfaces and the exhaust airflow. Experiments are carried out to validate the three-dimensional model, and comparisons prove that the model has considerable accuracy. In addition, both the numerical and experimental studies show that the hollow block ventilated wall can significantly reduce the heat transferred from outdoor environments to indoor rooms through ventilation in the summer. The effects of influential factors, including the airflow velocity, the inlet temperature of the airflow and the cavity size, on the thermal insulation performance of the hollow block ventilated wall are investigated based on the heat transfer model. Results show that the temperature of the inner surface of the hollow block ventilated wall at four orientations is reduced and ranges from 24.8 to 27.0 °C during a typical summer day. The heat flux through the inner surface is reduced by 55.08%, 55.07%, 56.03% and 55.19% respectively for the east, west, south, and north hollow block ventilated walls, indicating the energy saving potential of hollow block ventilated walls. The most critical factor is the cavity size. When the cavity dimension is constant, the influence of the airflow velocity on thermal insulation is much larger compared to the airflow temperature, and the suggested airflow rate is 1.3 m/s. Results show that a higher airflow rate, higher inlet airflow temperature, and larger cavity size, enable the hollow block ventilated wall to achieve better thermal insulation performance. | en_US |
| dcterms.accessRights | open access | en_US |
| dcterms.bibliographicCitation | Applied energy, 15 Dec. 2018, v. 232, p. 409-423 | en_US |
| dcterms.isPartOf | Applied energy | en_US |
| dcterms.issued | 2018-12-15 | - |
| dc.identifier.scopus | 2-s2.0-85054260135 | - |
| dc.identifier.eissn | 1872-9118 | en_US |
| dc.description.validate | 202310 bckw | en_US |
| dc.description.oa | Accepted Manuscript | en_US |
| dc.identifier.FolderNumber | BEEE-0437 | - |
| dc.description.fundingSource | Others | en_US |
| dc.description.fundingText | National Natural Science Foundation of China; Fundamental Research Funds of the Central Universities, HUST | en_US |
| dc.description.pubStatus | Published | en_US |
| dc.identifier.OPUS | 49647681 | - |
| dc.description.oaCategory | Green (AAM) | en_US |
| Appears in Collections: | Journal/Magazine Article | |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Huang_Effects_Key_Factors.pdf | Pre-Published version | 1.02 MB | Adobe PDF | View/Open |
Page views
97
Last Week
4
4
Last month
Citations as of Dec 21, 2025
Downloads
93
Citations as of Dec 21, 2025
SCOPUSTM
Citations
21
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
20
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.