| Title: | Testing and modelling an unglazed photovoltaic thermal collector for application in Sichuan Basin | Authors: | Yu, Y Long, E Chen, X Yang, H |
Issue Date: | 15-May-2019 | Source: | Applied energy, 15 May 2019, v. 242, p. 931-941 | Abstract: | This paper mainly investigated the performance of a low-cost roll-bond water-type photovoltaic thermal (PVT) collector from both experimental and modelling approaches under the climatic conditions of Sichuan Basin of China. The design and manufacturing process of the PVT prototype adopted the available commercial PV panels for convenience and for reducing the manufacturing cost. The experiment measured all the main properties of the developed PVT module. The excellent heat transfer performance of its roll-bond absorber plate was also validated by outdoor steady-state tests. Then, the steady-state numerical models were used to simulate the performance of the PVT prototype in TRNSYS. By comparing the simulation and experimental results, two robust models were selected which have their own advantages in charactering the thermal and electrical properties of the PVT collector. Through validating the numerical models with experimental data, the deviation between the simulated and the measured values was further reduced. In addition, a complete photovoltaic thermal–domestic hot water (PVT-DHW) system with such PVT collectors was developed in TRNSYS, by which the annual system output and efficiency were predicted and analysed. | Keywords: | PVT model Roll-bond absorber Thermo-laminating TRNSYS |
Publisher: | Pergamon Press | Journal: | Applied energy | ISSN: | 0306-2619 | EISSN: | 1872-9118 | DOI: | 10.1016/j.apenergy.2019.03.114 | Rights: | © 2019 Elsevier Ltd. All rights reserved. © 2019. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/. The following publication Yu, Y., Long, E., Chen, X., & Yang, H. (2019). Testing and modelling an unglazed photovoltaic thermal collector for application in sichuan basin. Applied Energy, 242, 931-941 is available at https://doi.org/10.1016/j.apenergy.2019.03.114. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Yu_Testing_Modelling_Unglazed.pdf | Pre-Published version | 1.49 MB | Adobe PDF | View/Open |
Page views
75
Last Week
2
2
Last month
Citations as of Dec 21, 2025
Downloads
141
Citations as of Dec 21, 2025
SCOPUSTM
Citations
53
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
48
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.