Title: Effects of wind direction and building array arrangement on airflow and contaminant distributions in the central space of buildings
Authors: Lee, KY 
Mak, CM 
Issue Date: Nov-2021
Source: Building and environment, Nov. 2021, v. 205, 108234
Abstract: Buildings are physical obstacles that diminish the benefits of wind by creating turbulence and reducing airflow velocities in urban settings. Particularly in the inner garden or amenities situated at the pedestrian level in the central space of a group of buildings, the efficiency of pollutant dispersion determines air quality and outdoor health. In this study, the effects of incident wind angles on wind velocity and pollutant distribution inside the central space of two building arrays arranged in ‘L’ and ‘U’ shapes were examined using computational fluid dynamics simulations. The ‘L’-shaped array performed better than the ‘U’-shaped array by forming a smaller low-wind-velocity (LWV) zone in the central space of the buildings (34.9%–76.11 % of the total space). The ‘L’-shaped array performed best at an incident wind angle of 225°, in which the LWV zone covered only 34.52 % of the central space. A 90° incident angle produced the largest LWV zone (81.80 %) for the ‘U’-shaped array. The ‘L’-shaped array generally distributed pollutants better than the ‘U’-shaped array. However, the ‘U’-shaped array with a 180° wind angle had a smaller high pollutant concentration area than the ‘L’-shaped array with a wind angle of 225° (Kc > 218.5 covering only 0.37 %). The worst vertical dispersion corresponded to a 135° wind angle for the ‘L’-shaped array, which recorded the highest Kc at the mid-level of the building. In conclusion, the appropriate selection of building array designs and their orientations allows for the most effective use of wind flow to enhance ventilation and pollutant dispersion.
Keywords: Airflow and contaminant dispersion
Building arrays
Building central space ventilation
Incident wind angles
Publisher: Pergamon Press
Journal: Building and environment 
ISSN: 0360-1323
EISSN: 1873-684X
DOI: 10.1016/j.buildenv.2021.108234
Rights: © 2021 Elsevier Ltd. All rights reserved.
© 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Lee, K. Y., & Mak, C. M. (2021). Effects of wind direction and building array arrangement on airflow and contaminant distributions in the central space of buildings. Building and Environment, 205, 108234 is available at https://dx.doi.org/10.1016/j.buildenv.2021.108234.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Lee_Effects_Wind_Direction.pdfPre-Published version3.33 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

93
Last Week
4
Last month
Citations as of Dec 21, 2025

Downloads

143
Citations as of Dec 21, 2025

SCOPUSTM   
Citations

47
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

40
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.