Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/102693
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorSchool of Fashion and Textiles-
dc.creatorShi, QQen_US
dc.creatorLi, PLen_US
dc.creatorYick, KLen_US
dc.creatorJiao, Jen_US
dc.creatorLiu, QLen_US
dc.date.accessioned2023-11-07T05:55:08Z-
dc.date.available2023-11-07T05:55:08Z-
dc.identifier.issn1661-7827en_US
dc.identifier.urihttp://hdl.handle.net/10397/102693-
dc.language.isoenen_US
dc.publisherMolecular Diversity Preservation International (MDPI)en_US
dc.rights© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).en_US
dc.rightsThe following publication Shi, Q. Q., Li, P. L., Yick, K. L., Jiao, J., & Liu, Q. L. (2022). Influence of Contoured Insoles with Different Materials on Kinematics and Kinetics Changes in Diabetic Elderly during Gait. International Journal of Environmental Research and Public Health, 19(19), 12502 is available at https://doi.org/10.3390/ijerph191912502.en_US
dc.subjectContoured insolesen_US
dc.subjectDiabetic footen_US
dc.subjectGait patternen_US
dc.subjectInsole materialsen_US
dc.subjectPeak plantar pressureen_US
dc.titleInfluence of contoured insoles with different materials on kinematics and kinetics changes in diabetic elderly during gaiten_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume19en_US
dc.identifier.issue19en_US
dc.identifier.doi10.3390/ijerph191912502en_US
dcterms.abstractBackground: Alterations in the lower limb kinematics and kinetics of diabetic patients have been reported in previous studies. Inappropriate choices of orthopedic insole materials, however, fail to prevent diabetic foot ulcers and modify abnormal gait. The aim of this study was to quantitatively compare the effects of contoured insoles with different materials on the kinematics of and kinetics changes in the diabetic elderly during gait. Methods: There were 21 diabetic patients who participated in this study. Three-dimensional (3D) experimental contoured insoles constructed of soft (i.e., Nora Lunalastik EVA and PORON® Medical 4708) and rigid (i.e., Nora Lunalight A fresh and Pe-Lite) materials with Langer Biomechanics longitudinal PPT® arch pads were adopted. An eight-camera motion capture system (VICON), two force plates, and an insole measurement system—Pedar® with 99 sensors—were utilized to obtain the kinematics and kinetics data. The plug-in lower body gait model landmarks were used for dynamic data acquisition during gait. The corresponding data from five gait cycles were selected and calculated. Results: The range of motions (ROMs) of the ankle joint (p = 0.001) and knee joint (p = 0.044) were significantly influenced when the contoured insoles were worn in comparison to the barefoot condition. The joint moments of the lower limbs with maximum ankle plantarflexion during the loading response and maximum knee and hip flexions were significantly influenced by the use of contoured insoles with different materials in the diabetic elderly. The peak plantar pressure (PPP) of the forefoot (p < 0.001), midfoot (p = 0.009), and rearfoot (p < 0.001) was significantly offloaded by the contoured insoles during the stance phase, whilst the PPP of the rearfoot (p < 0.001) was significantly offloaded during the swing phase. Conclusions: The contoured insoles, especially those constructed with soft materials, significantly offloaded the PPP during gait—hence accommodating certain abnormal gait patterns more effectively compared to going barefoot.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationInternational journal of environmental research and public health, Oct. 2022, v. 19, no. 19, 12502en_US
dcterms.isPartOfInternational journal of environmental research and public healthen_US
dcterms.issued2022-10-
dc.identifier.scopus2-s2.0-85139927959-
dc.identifier.pmid36231798-
dc.identifier.eissn1660-4601en_US
dc.identifier.artn12502en_US
dc.description.validate202311 bckw-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_Others-
dc.description.fundingSourceOthersen_US
dc.description.fundingTextLaboratory for Artificial Intelligence in Design under the InnoHK Research Clusters, Hong Kong Special Administrative Region Governmenten_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryCCen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
ijerph-19-12502-v2.pdf3.23 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

150
Last Week
8
Last month
Citations as of Nov 9, 2025

Downloads

101
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

8
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

8
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.