Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/102691
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorSchool of Fashion and Textiles-
dc.creatorShi, QQen_US
dc.creatorLi, PLen_US
dc.creatorYick, KLen_US
dc.creatorLi, NWen_US
dc.creatorJiao, Jen_US
dc.date.accessioned2023-11-07T05:55:07Z-
dc.date.available2023-11-07T05:55:07Z-
dc.identifier.urihttp://hdl.handle.net/10397/102691-
dc.language.isoenen_US
dc.publisherNature Publishing Groupen_US
dc.rights© The Author(s) 2022en_US
dc.rightsOpen Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.en_US
dc.rightsThe following publication Shi, Q. Q., Li, P. L., Yick, K. L., Li, N. W., & Jiao, J. (2022). Effects of contoured insoles with different materials on plantar pressure offloading in diabetic elderly during gait. Scientific Reports, 12(1), 15395 is available at https://doi.org/10.1038/s41598-022-19814-0.en_US
dc.titleEffects of contoured insoles with different materials on plantar pressure offloading in diabetic elderly during gaiten_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume12en_US
dc.identifier.doi10.1038/s41598-022-19814-0en_US
dcterms.abstractTo investigate the effect of contoured insoles constructed of different insole materials, including Nora Lunalastik EVA, Nora Lunalight A fresh, Pe-Lite, and PORON Medical 4708 with Langer Biomechanics longitudinal PPT arch pads on offloading plantar pressure on the foot of the elderly with Type 1 or 2 diabetes during gait. Twenty-two elderly with Type 1 or 2 diabetes participated in the study. Their plantar pressure was measured by using an insole measurement system, while the participants walked 10 m in their bare feet or used each experimental insole in random order. The plantar surface was divided into four specific regions including the toes, forefoot, midfoot, and rearfoot. The mean peak pressure (MPP) and pressure–time integral (PTI) of ten steps with or without wearing one of the four insoles were analyzed on the dominant foot and the four specific plantar regions. After completion of the activities, the participants scored each insole from 1 (the least comfortable) to 10 (the most comfortable). The analysis of variance (ANOVA) factor of the insoles had significant effects on the MPP (P < 0.001) and PTI (P = 0.004) in the dominant foot during gait. Pairwise comparison results showed that the MPP and PTI in the dominant foot were significantly lower (P < 0.001) with PORON Medical 4708 than barefoot, Nora Lunalight A fresh, and Pe-Lite. Additionally, the insole materials had a significant effect for the forefoot (P < 0.001) and rearfoot (P < 0.001) in terms of the MPP and PTI compared with the barefoot condition during gait. Regardless of the plantar region, the MPP and PTI values were the lowest when PORON Medical 4708 was used as the insole material among four insole materials. Meanwhile, a significantly lower MPP and PTI can be found in the forefoot and rearfoot with the use of the four experimental insoles when compared with barefoot. The soft insole materials (i.e., PORON medical 4708 and Nora Lunalastik EVA) had a better performance than the rigid insole materials (i.e., Nora Lunalight A fresh, and Pe-Lite) on plantar pressure offloading for diabetic elderly.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationScientific reports, 2022, v. 12, 15395en_US
dcterms.isPartOfScientific reportsen_US
dcterms.issued2022-
dc.identifier.scopus2-s2.0-85137824171-
dc.identifier.pmid36100637-
dc.identifier.eissn2045-2322en_US
dc.identifier.artn15395en_US
dc.description.validate202311 bckw-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_Others-
dc.description.fundingSourceOthersen_US
dc.description.fundingTextLaboratory for Artifcial Intelligence in Design under the InnoHK Research Clusters, Hong Kong Special Administrative Region Governmenten_US
dc.description.pubStatusPublisheden_US
dc.description.oaCategoryCCen_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
s41598-022-19814-0.pdf3.92 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

109
Last Week
7
Last month
Citations as of Nov 9, 2025

Downloads

59
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

26
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

22
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.