Title: Transient frequency response based leak detection in water supply pipeline systems with branched and looped junctions
Authors: Duan, HF 
Issue Date: 1-Jan-2017
Source: Journal of hydroinformatics, 1 Jan. 2017, v. 19, no. 1, p. 17-30
Abstract: The transient frequency response (TFR) method has been widely developed and applied in the literature to identify and detect potential defects such as leakage and blockage in water supply pipe systems. This type of method was found to be efficient, economic and non-intrusive for pipeline condition assessment and diagnosis, but its applications so far are mainly limited to single and simple pipeline systems. This paper aims to extend the TFR-based leak detection method to relatively more complex pipeline connection situations. The branched and looped pipe junctions are firstly investigated for their influences to the system TFR, so that their effects can be characterized and separated from the effect of other components and potential leakage defects in the system. The leak-induced patterns of transient responses are derived analytically using the transfer matrix method for systems with different pipe junctions, which thereafter are used for the analysis of pipe leakage conditions in the system. The developed method is validated through different numerical experiments in this study. Based on the analytical analysis and numerical results, the applicability and accuracy as well as the limitations of the developed TFR-based leak detection method are discussed for practical applications in the paper.
Keywords: Leak detection
Pipe junction
Transfer matrix
Transient frequency response
Transient tests
Water pipeline system
Publisher: International Water Association Publishing
Journal: Journal of hydroinformatics 
ISSN: 1464-7141
EISSN: 1465-1734
DOI: 10.2166/hydro.2016.008
Rights: © IWA Publishing 2017
This is the accepted manuscript of the following article: Huan-Feng Duan; Transient frequency response based leak detection in water supply pipeline systems with branched and looped junctions. Journal of Hydroinformatics 1 January 2017; 19 (1): 17–30, which has been published in final form at https://doi.org/10.2166/hydro.2016.008.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Duan_Transient_Frequency_Response.pdfPre-Published version1.5 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

129
Last Week
4
Last month
Citations as of Dec 21, 2025

Downloads

242
Citations as of Dec 21, 2025

SCOPUSTM   
Citations

80
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

77
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.