Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/102264
PIRA download icon_1.1View/Download Full Text
Title: Effect of contacting surface on the performance of thin‐film force and pressure sensors
Authors: Tang, KPM 
Yick, KL 
Li, PL 
Yip, J 
Or, KH 
Chau, KH 
Issue Date: Dec-2020
Source: Sensors (Switzerland), Dec. 2020, v. 20, no. 23, 6863
Abstract: Flexible force and pressure sensors are important for assessing the wear comfort of tightly fitting apparel. Their accuracy and repeatability depend on the sensor itself and the contacting surface. Measurements of the contact pressure on soft surfaces like human skin tend to be erroneous, which could be due to incorrect sensor calibrations. This study aims to examine the effects of human body parameters such as the hardness and temperature of the contacting surface by using a custom‐made calibration setup and investigating the incorporation of rigid discs on the sensor surface. Two commercial force sensors, FlexiForce and SingleTact, and one pressure sensor, Pliance X, are used in the investigation. The findings reveal that adding rigid discs on both sides of the force sensors improves their sensitivity. Systematic calibration has been performed on the surfaces with different temperatures and hardness. The results show that FlexiForce and Pliance X tend to be affected by the changes in surface temperature and surface hardness. Prolonged testing time shows that the time dependence of SingleTact and Pliance X sensor is lower, which suggests that they are more suitable for lengthier evaluations in which interface pressure is exerted on the human body. In brief, sensor attachment and proper calibration should be thoroughly considered before using sensors for applications on soft surfaces, like the human body.
Keywords: Force sensor
Hardness
Pressure comfort
Pressure sensor
Sensor evaluation
Temperature
Publisher: Molecular Diversity Preservation International (MDPI)
Journal: Sensors (Switzerland) 
ISSN: 1424-8220
DOI: 10.3390/s20236863
Rights: © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
The following publication Tang, K. P. M., Yick, K. L., Li, P. L., Yip, J., Or, K. H., & Chau, K. H. (2020). Effect of contacting surface on the performance of thin-film force and pressure sensors. Sensors, 20(23), 6863 is available at https://doi.org/10.3390/s20236863.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
sensors-20-06863-v2.pdf4.65 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

98
Citations as of Apr 13, 2025

Downloads

46
Citations as of Apr 13, 2025

SCOPUSTM   
Citations

8
Citations as of Apr 24, 2025

WEB OF SCIENCETM
Citations

8
Citations as of Apr 24, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.