Please use this identifier to cite or link to this item:
http://hdl.handle.net/10397/101241
| Title: | Laboratory evaluation of electromagnetic density gauges for hot-mix asphalt mixture density measurement | Authors: | Leng, Z Zhang, Z Zhang, Y Wang, Y Yu, H Ling, T |
Issue Date: | 15-Jan-2018 | Source: | Construction and building materials, 15 Jan 2018, v. 158, p. 1055-1064 | Abstract: | This paper presents a laboratory study aiming to evaluate the performance of electromagnetic (EM) density gauges as a non-destructive tool for hot mix asphalt (HMA) density measurement. In total, 36 HMA testing slabs with different compositions were prepared in laboratory. EM density gauge data were collected from these slabs using two common types of gauges, i.e., PQI 301 and PaveTracker 2701B, and compared with their bulk densities measured by the standard saturated surface dry (SSD) method. It was found that measurement direction, asphalt binder content, mixture air void content, and thickness of the testing slabs do not affect the accuracy of the EM density gauges. However, EM density gauge measurements are affected by the presence of moisture, gradation of asphalt mixture and gauge calibration method. It was also concluded that the accuracy of PaveTracker with mix calibration is comparable to that of the conventional standard method. | Keywords: | Asphalt mixture Density Electromagnetic density gauge Evaluation |
Publisher: | Elsevier | Journal: | Construction and building materials | ISSN: | 0950-0618 | DOI: | 10.1016/j.conbuildmat.2017.09.186 | Rights: | © 2017 Elsevier Ltd. All rights reserved. © 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/ The following publication Leng, Z., Zhang, Z., Zhang, Y., Wang, Y., Yu, H., & Ling, T. (2018). Laboratory evaluation of electromagnetic density gauges for hot-mix asphalt mixture density measurement. Construction and Building Materials, 158, 1055-1064 is available at https://doi.org/10.1016/j.conbuildmat.2017.09.186. |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Leng_Laboratory_Evaluation_Electromagnetic.pdf | Pre-Published version | 1.61 MB | Adobe PDF | View/Open |
Page views
100
Last Week
0
0
Last month
Citations as of Dec 21, 2025
Downloads
115
Citations as of Dec 21, 2025
SCOPUSTM
Citations
34
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
31
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.