Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/101041
PIRA download icon_1.1View/Download Full Text
Title: Behaviour of concrete-filled cold-formed high strength steel circular stub columns
Authors: Su, M
Cai, Y 
Chen, X
Young, B 
Issue Date: Dec-2020
Source: Thin-walled structures, Dec. 2020, v. 157, 107078
Abstract: This paper presents the experimental and numerical investigations of concrete-filled cold-formed high strength steel (CFHSS) circular stub columns. Firstly, a series of tests was conducted on CFHSS circular tubular sections infilled with three different concrete grades, i.e., C40, C80 and C120. The CFHSS circular tubular sections had the nominal 0.2% proof stress (yield stress) up to 1100 MPa. The test specimens were subjected to uniform axial compression The ultimate loads and failure modes of the specimens were obtained and reported in this paper. Secondly, an extensive numerical study accounting for the confinement effect, as well as the non-linearities of materials, geometry and contacts was performed. Upon validation against the test results, a parametric investigation was conducted. A wide range of the cross-section dimensions and section slenderness of CFHSS circular tubular sections infilled with different grades of concrete were considered. The structural behaviour of concrete-filled CFHSS stub columns was investigated, including the ultimate load, end shortening, strength enhancement index and ductility index. Finally, the experimental and numerical results were used to assess the suitability of the design equations specified in the existing American Specifications (AISC and ACI), European Code (EC4) and Japanese Code (AIJ) for the compressive strength of the concrete-filled CFHSS circular stub columns. It was found that the predictions from the existing international design specifications were generally conservative, except for EC4. The predictions by the AIJ are the least conservative and least scattered. However, by using the effective section area of steel tubes for slender cross sections, EC4 provided the most accurate and consistent predictions than the other design specifications.
Keywords: Circular hollow sections
Cold-formed steel
Concrete-filled steel tube
High strength steel
Stub columns
Publisher: Pergamon Press
Journal: Thin-walled structures 
ISSN: 0263-8231
EISSN: 1879-3223
DOI: 10.1016/j.tws.2020.107078
Rights: © 2020 Elsevier Ltd. All rights reserved.
© 2020. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Su, M., Cai, Y., Chen, X., & Young, B. (2020). Behaviour of concrete-filled cold-formed high strength steel circular stub columns. Thin-Walled Structures, 157, 107078 is available at https://doi.org/10.1016/j.tws.2020.107078.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Cai_Behaviour_Concrete-Filled_Cold-Formed.pdfPre-Published version1.81 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

142
Last Week
2
Last month
Citations as of Nov 9, 2025

Downloads

128
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

56
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

47
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.