Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/100287
PIRA download icon_1.1View/Download Full Text
Title: Highly sensitive cell concentration detection by resonant optical tunneling effect
Authors: Jian, A
Zou, L
Bai, G
Duan, Q
Zhang, Y
Zhang, Q
Sang, S
Zhang, X 
Issue Date: 1-Jun-2019
Source: Journal of lightwave technology, 1 June 2019, v. 37, no. 11, p. 2800-2806
Abstract: This paper presents an original design for a volume refractive index (RI) sensor for cell concentration detection based on the unique resonant optical tunneling effect (ROTE). In this design, the solution sample is introduced into the ROTE resonant cavity, whose reflection spectrum presents a large shift of its resonant dip in response to the tiny change of the solution RI. Performance calibration using the polystyrene particle solution indicates that the sensitivity is 19,000 nm/RIU and the total Q factor is 620. Experiments with hepatoma cells have obtained sensitivity values as high as 2.53 nm/(amol/ml) and a detection limit of 1.2 × 105 cells/ml. Compared with previously reported optical cell sensors, this original work implements the ROTE mechanism for the first time and presents superior device performance. Thus, the proposed design has a high potential for use in biomedical applications, such as drug discovery, cell research, and medical diagnoses.
Keywords: Cell concentration
Figure of merit
Optical biosensor
Resonant optical tunneling effect
Publisher: Institute of Electrical and Electronics Engineers
Journal: Journal of lightwave technology 
ISSN: 0733-8724
EISSN: 1558-2213
DOI: 10.1109/JLT.2019.2907786
Rights: © 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
The following publication Jian, A., Zou, L., Bai, G., Duan, Q., Zhang, Y., Zhang, Q., ... & Zhang, X. (2019). Highly sensitive cell concentration detection by resonant optical tunneling effect. Journal of Lightwave Technology, 37(11), 2800-2806 is available at https://doi.org/10.1109/JLT.2019.2907786.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Zhang_Highly_Sensitive_Cell.pdfPre-Published version1.97 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

71
Citations as of Apr 14, 2025

Downloads

55
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

16
Citations as of Sep 12, 2025

WEB OF SCIENCETM
Citations

13
Citations as of Oct 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.