Title: Fresh air pre-cooling and energy recovery by using indirect evaporative cooling in hot and humid region - A case study in Hong Kong
Authors: Chen, Y
Luo, Y
Yang, H 
Issue Date: 2014
Source: Energy procedia, 2014, v. 61, no. , p. 126-130
Abstract: Evaporative cooling (EC) is an energy efficient and environmental friendly technology which uses water evaporation to absorb the heat from surroundings and produce cooling air. EC has limited application cases in hot and humid regions because of the relatively low cooling capacity. In recent years, the study on hybrid EC and traditional mechanical cooling becomes the trend to break the region limitation of the technology. This paper carries out a case study for applying the Regenerative Indirect Evaporative Cooling System (RIECS) to an all-fresh-air hybrid airconditioning system of a wet market in Hong Kong. The condense water from an air-handling unit (AHU) is collected and used as cooling medium sprayed onto the heat exchanger of an IEC equipment. At the same time, the contaminative and exhausted air from the wet market returns to the IEC equipment to cool the intake fresh air, so that the fresh air pre-cooling before it enters to the AHUs is realized. The energy saving and economic efficiency were analyzed and compared among RIECS, rotating heat recovery wheel system and the A/C system without heat recovery. The results show that RIEC system has the largest annual energy saving potential with a payback period of 2.9 years, which shows a great potential of its application in Hong Kong.
Keywords: Energy and economic analysis
Evaporative cooling
Fresh air pre-cooling
Hot and humid regions
Publisher: Elsevier
Journal: Energy procedia 
EISSN: 1876-6102
DOI: 10.1016/j.egypro.2014.11.922
Description: 6th International Conference on Applied Energy, ICAE 2014, Taiwan, 30 May -2 June 2014
Rights: © 2014 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/3.0/).
The following publication Chen, Y., Luo, Y., & Yang, H. (2014). Fresh air pre-cooling and energy recovery by using indirect evaporative cooling in hot and humid region - A case study in Hong Kong. Energy Procedia, 61, 126-130 is available athttps://dx.doi.org/10.1016/j.egypro.2014.11.922
Appears in Collections:Conference Paper

Files in This Item:
File Description SizeFormat 
Chen_Fresh_Air_Pre-cooling.pdf376.01 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

174
Last Week
1
Last month
Citations as of Apr 14, 2024

Downloads

57
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

18
Last Week
1
Last month
0
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

16
Last Week
0
Last month
0
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.