Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/91372
PIRA download icon_1.1View/Download Full Text
Title: Time-variant positive air pressure in drainage stacks as a pathogen transmission pathway of COVID-19
Authors: Wong, LT 
Mui, KW 
Cheng, CL
Leung, PHM 
Issue Date: Jun-2021
Source: International journal of environmental research and public health, June 2021, v. 18, no. 11, 6068
Abstract: Time-variant positive air pressure in a drainage stack poses a risk of pathogenic virus transmission into a habitable space, however, the excessive risk and its significance have not yet been sufficiently addressed for drainage system designs. This study proposes a novel measure for the probable pathogenic virus transmission risk of a high-rise drainage stack with the occurrence of positive air pressure. The proposed approach is based on time-variant positive air pressures measured in a 38 m high drainage stack of a full-scale experimental tower under steady flow conditions of flow rate 1–4 Ls−1 discharging at a height between 15 m to 33 m above the stack base. The maximum pressure and probabilistic positive air pressures in the discharging stack ventilation section with no water (Zone A of the discharging drainage stack) were determined. It was demonstrated that the positive air pressures were lower in frequency as compared with those in other stack zones and could propagate along the upper 1/3 portion of the ventilation pipe (H’ ≥ 0.63) towards the ventilation opening at the rooftop. As the probabilistic positive pressures at a stack height were found to be related to the water discharging height and flow rate, a risk model of positive air pressure is proposed. Taking the 119th, 124th, 140th and 11,547th COVID-19 cases of an epidemiological investigation in Hong Kong as a baseline of concern, excessive risk of system overuse was evaluated. The results showed that for a 20–80% increase in the frequency of discharge flow rate, the number of floors identified at risk increased from 1 to 9 and 1 to 6 in the 34-and 25-storey residential buildings, respectively. The outcome can apply to facilities planning for self-quarantine arrangements in high-rise buildings where pathogenic virus transmission associated with drainage system overuse is a concern.
Keywords: COVID-19
Drainage stack
Experiment
High-rise
Pathogen transmission
Positive air pressure
Publisher: Molecular Diversity Preservation International (MDPI)
Journal: International journal of environmental research and public health 
ISSN: 1661-7827
EISSN: 1660-4601
DOI: 10.3390/ijerph18116068
Rights: © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/4.0/).
The following publication Wong, L.-T.; Mui, K.-W.; Cheng, C.-L.; Leung, P.H.-M. Time-Variant Positive Air Pressure in Drainage Stacks as a Pathogen Transmission Pathway of COVID-19. Int. J. Environ. Res. Public Health 2021, 18, 6068 is available at https://doi.org/10.3390/ijerph18116068
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
ijerph-18-06068.pdf3.26 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

61
Last Week
1
Last month
Citations as of Apr 14, 2024

Downloads

55
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

10
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

8
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.