Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/99700
PIRA download icon_1.1View/Download Full Text
Title: A novel dual-element catheter for improving non-uniform rotational distortion in intravascular ultrasound
Authors: Liu, B
Su, M 
Zhang, Z
Liu, R
Sun, L 
Zheng, H
Qiu, W
Issue Date: Jun-2023
Source: IEEE transactions on biomedical engineering, June 2023, v. 70, no. 6, p. 1768-1774
Abstract: For the early diagnosis of atherosclerosis and interventions, intravascular ultrasound (IVUS) is a valuable tool for intravascular luminal imaging. Compared with the array-based method, mechanically rotating IVUS catheters dominate the clinical applications because of their less complexity and better suitability for high-frequency ultrasound imaging. However, mechanically rotating catheters are suffering from non-uniform rotational distortion (NURD) which hinders accurate image acquisition. In this study, a dual-element imaging catheter is proposed, in which two elements with the same frequency and similar performance are assembled in a back-to-back arrangement. When the catheter encounters a NURD due to acute bending, the abnormal image of one element can be replaced by the normal image of the opposite element, thus eliminating the NURD in the reconstructed image. Moreover, two images can be obtained in one rotation and the imaging frame rate is doubled in the absence of NURD. The performance of the two elements was quantitatively assessed by a wire phantom. And the complementary imaging protocols were evaluated by a tissue phantom and ex vivo porcine vessel. The results show that the proposed strategy can be promising in clinical studies.
Keywords: Intravascular ultrasound (IVUS)
Non-uniform rotation distortion (NURD)
Dual-element catheter
Ultrasound imaging system
Publisher: Institute of Electrical and Electronics Engineers
Journal: IEEE transactions on biomedical engineering 
ISSN: 0018-9294
EISSN: 1558-2531
DOI: 10.1109/TBME.2022.3226955
Rights: © 2022 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
The following publication B. Liu et al., "A Novel Dual-Element Catheter for Improving Non-Uniform Rotational Distortion in Intravascular Ultrasound," in IEEE Transactions on Biomedical Engineering, vol. 70, no. 6, pp. 1768-1774, June 2023 is available at https://doi.org/10.1109/TBME.2022.3226955.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Liu_Novel_Dual-Element_Catheter.pdfPre-Published version1.34 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

95
Citations as of Apr 14, 2025

Downloads

292
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

3
Citations as of Jun 21, 2024

WEB OF SCIENCETM
Citations

3
Citations as of Oct 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.