Title: Experimental investigation on recycled aggregate concrete filled steel tubular stub columns under axial compression
Authors: de Azevedo, VDS
de Lima, LRO
Vellasco, PCGDS
Tavares, MEDN
Chan, TM 
Issue Date: Dec-2021
Source: Journal of constructional steel research, Dec. 2021, v. 187, 106930
Abstract: This paper presents an extensive experimental investigation of the circular recycled aggregate concrete filled steel tubes (RACFST) stub columns under to axial compression to assess their cross-section behaviour. Recycled aggregate concrete is a sustainable concrete produced with recycled coarse aggregate (RAC) from demolition wastes generally used to fabricate non-structural elements. When compared with natural coarse aggregate (NCA), the recycled coarse aggregate presents lower mechanical properties due to physical and chemical changes that occurred during the recycling process, and thus the resulting RAC possess lower strength than the conventional natural aggregate concrete. However, the confinement provided by the circular steel tube can increase the strength and ductility of RAC in recycled aggregate concrete filled steel tubes (RACFST) columns. The test programme presented in this paper comprised twenty-three composite columns with replacement ratios (the mass percentages of the NCA replaced by RCA in concrete) corresponding to 0% (nature coarse aggregate), 30 and 50% (recycled aggregate concrete), plus four steel columns used for comparison. The experiments have shown that, as anticipated, the concrete core enhances the composite section load-carrying capacity. However, the control over the contents of this concrete core influences the composite section's ductility. If the fill material presents a brittle behaviour, stress redistributions occur in both steel and concrete to compensate for this effect. Since the behaviour of natural aggregate concrete filled steel tubes (NACFST) and RACFST columns are similar, the present paper starts from a study based on a comparative assessment of the recommendations presented in ABNT NBR 8800, ABNT NBR 16239, AISC 360–16, Eurocode 4 and Australian/New Zealand AS/NZS 2327 design standards. These design recommendations proved to be consistent and in line with the performed experiments. Additionally, the results indicated that the cross-section slenderness ratio (D/t) and the confinement ratio directly influence the composite section response.
Keywords: Composite columns
Experimental analysis
Recycled aggregate concrete
Sustainability
Publisher: Elsevier
Journal: Journal of constructional steel research 
ISSN: 0143-974X
EISSN: 1873-5983
DOI: 10.1016/j.jcsr.2021.106930
Rights: © 2021 Elsevier Ltd. All rights reserved.
© 2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication de Azevedo, V. d. S., de Lima, L. R. O., Vellasco, P. C. G. d. S., Tavares, M. E. d. N., & Chan, T.-M. (2021). Experimental investigation on recycled aggregate concrete filled steel tubular stub columns under axial compression. Journal of Constructional Steel Research, 187, 106930 is available at https://dx.doi.org/10.1016/j.jcsr.2021.106930.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Chan_Experimental_Investigation_Recycled.pdfPre-Published version3.41 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

74
Last Week
0
Last month
Citations as of Dec 21, 2025

Downloads

131
Citations as of Dec 21, 2025

SCOPUSTM   
Citations

53
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

48
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.