Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/97310
PIRA download icon_1.1View/Download Full Text
Title: Utility of a unilateral accelerometer for monitoring upper extremity use in subacute stroke patients after discharge from hospital
Authors: Wei, WXJ 
Fong, KNK 
Chung, RCK 
Myint, JMWW
Cheung, HKY
Chow, ESL
Issue Date: 2019
Source: Assistive technology, 2019, v. 31, no. 4, p. 193-198
Abstract: This study was to investigate the utility of a unilateral accelerometer, which is commonly used for monitoring upper extremity performance, in subacute stroke patients by comparing its use with other upper extremity assessments. Twenty-four participants were recruited and required to wear an accelerometer on the affected wrist for 3 hours daily for the first 4 weeks after discharge from hospital. Assessments included Fugl-Meyer Assessment–Upper Extremity (FMA-UE), Action Research Arm Test (ARAT), Box and Block Test (BBT), and self-reporting Motor Activity Log (MAL). Assessments were made at 0, 4, 8, and 12 weeks after hospital discharge. How long the device was worn, movement amount, and movement percentage were extracted from the accelerometer. Throughout the 12-week observation, significant improvements in the participants were shown by the FMA-UE, ARAT, and BBT (p < 0.001, p = 0.026, and p < 0.001, respectively), but no significant change could be found using MAL or the accelerometer parameters across time (p = 0.068 to 0.999). There was moderate-to-good correlation among the assessments; however, no significant correlation was obtained between any of the assessments and the accelerometer data. We suggest that the unilateral accelerometer might not be useful to reflect actual arm functions in daily activities.
Keywords: Accelerometer
Learned non-use
Paretic upper extremity
Stroke
Publisher: Taylor & Francis Inc.
Journal: Assistive technology 
ISSN: 1040-0435
DOI: 10.1080/10400435.2017.1414085
Rights: © 2018 RESNA
This is an Accepted Manuscript of an article published by Taylor & Francis in Assistive Technology on 25 Jan 2018 (published online), available at: http://www.tandfonline.com/10.1080/10400435.2017.1414085.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Fong_Utility_Unilateral_Accelerometer.pdfPre-Published version1 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

72
Citations as of Apr 14, 2025

Downloads

39
Citations as of Apr 14, 2025

SCOPUSTM   
Citations

9
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

7
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.