Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/96517
PIRA download icon_1.1View/Download Full Text
Title: The clinical utility of two high-throughput 16S rRNA gene sequencing workflows for taxonomic assignment of unidentifiable bacterial pathogens in matrix-assisted laser desorption ionization-time of flight mass spectrometry
Authors: Lao, HY 
Ng, TTL 
Wong, RYL
Wong, CST
Lee, LK 
Wong, DSH 
Chan, CTM 
Jim, SHC 
Leung, JSL 
Lo, HWH 
Wong, ITF 
Yau, MCY
Lam, JYW
Wu, AKL
Siu, GKH 
Issue Date: Jan-2022
Source: Journal of clinical microbiology, Jan. 2022, v. 60, no. 1, e01769-21
Abstract: Bacterial pathogens that cannot be identified using matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) are occasionally encountered in clinical laboratories. The 16S rRNA gene is often used for sequence-based analysis to identify these bacterial species. Nevertheless, traditional Sanger sequencing is laborious, time-consuming, and low throughput. Here, we compared two commercially available 16S rRNA gene sequencing tests that are based on Illumina and Nanopore sequencing technologies, respectively, in their ability to identify the species of 172 clinical isolates that failed to be identified by MALDI-TOF MS. Sequencing data were analyzed by the respective built-in programs (MiSeq Reporter software of Illumina and Epi2me of Nanopore) and BLAST1 (v2.11.0). Their agreement with Sanger sequencing on species-level identification was determined. Discrepancies were resolved by whole-genome sequencing. The diagnostic accuracy of each workflow was determined using the composite sequencing result as the reference standard. Despite the high base-calling accuracy of Illumina sequencing, we demonstrated that the Nanopore workflow had a higher taxonomic resolution at the species level. Using built-in analysis algorithms, the concordance of Sanger 16S with the Illumina and Nanopore workflows was 33.14% and 87.79%, respectively. The agreement was 65.70% and 83.14%, respectively, when BLAST1 was used for analysis. Compared with the reference standard, the diagnostic accuracy of Nanopore 16S was 96.36%, which was identical to that of Sanger 16S and better than that of Illumina 16S (69.07%). The turnaround time of the Illumina workflow and the Nanopore workflow was 78 h and 8.25 h, respectively. The per-sample cost of the Illumina and Nanopore workflows was US$28.5 and US$17.7, respectively.
Keywords: 16S rRNA gene
Bacterial species
Illumina sequencing
Nanopore sequencing
Sanger sequencing
Publisher: American Society for Microbiology
Journal: Journal of clinical microbiology 
ISSN: 0095-1137
EISSN: 1098-660X
DOI: 10.1128/JCM.01769-21
Rights: © 2022 Lao et al. This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license (https://creativecommons.org/licenses/by/4.0/).
The following publication Lao, H. Y., Ng, T. T. L., Wong, R. Y. L., Wong, C. S. T., Lee, L. K., Wong, D. S. H., ... & Siu, G. K. H. (2022). The Clinical Utility of Two High-Throughput 16S rRNA Gene Sequencing Workflows for Taxonomic Assignment of Unidentifiable Bacterial Pathogens in Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry. Journal of clinical microbiology, 60(1), e01769-21 is available at https://doi.org/10.1128/JCM.01769-21.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
JCM.01769-21.pdf1.92 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

77
Last Week
4
Last month
Citations as of Apr 28, 2024

Downloads

52
Citations as of Apr 28, 2024

SCOPUSTM   
Citations

9
Citations as of May 3, 2024

WEB OF SCIENCETM
Citations

7
Citations as of May 2, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.