Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/96192
PIRA download icon_1.1View/Download Full Text
Title: A real-time freehand 3D ultrasound imaging method for scoliosis assessment
Authors: Jiang, W 
Chen, X
Yu, C
Issue Date: Aug-2022
Source: Journal of applied clinical medical physics, Aug. 2022, v. 23, no. 8, e13709
Abstract: Real-time 3D ultrasound has gained popularity in many fields because it can provide interactive feedback to help acquire high-quality images or to conduct timely diagnosis. However, no comprehensive study has been reported on such an imaging method for scoliosis evaluation due to the complexity of this application. Meanwhile, the use of radiation-free assessment of scoliosis is becoming increasingly popular. This study developed a real-time 3D ultrasound imaging method for scoliosis assessment based on an incremental imaging method. In vivo experiments involving 36 patients with scoliosis were performed to test the performance of the proposed method. This new imaging method achieved a mean incremental frame rate of 82.7 ± 11.0 frames/s. The high repeatability of the intra-operator test (intraclass correlation coefficient [ICC] = 0.92) and inter-operator test (ICC = 0.91) demonstrated that the new method was very reliable. The result of spinous process angles obtained by the new method was linearly correlated (y = 0.97x, R2 = 0.88) with that obtained by conventional 3D reconstruction. These results suggested that the newly developed imaging method can provide real-time ultrasound imaging for scoliosis evaluation while preserving the comparative image quality of the conventional 3D reconstruction method.
Keywords: 3D reconstruction
Freehand 3D ultrasound
Incremental imaging
Real-time imaging
Scoliosis
Spine ultrasound
Publisher: American College of Medical Physics
Journal: Journal of applied clinical medical physics 
EISSN: 1526-9914
DOI: 10.1002/acm2.13709
Rights: © 2022 The Authors.Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine.
This is an open access article under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
The following publication Jiang, W, Chen, X, Yu, C. A real-time freehand 3D ultrasound imaging method for scoliosis assessment. J Appl Clin Med Phys. 2022; 23:e13709 is available at https://doi.org/10.1002/acm2.13709.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Jiang_ Real‐time_Freehand_Ultrasound.pdf811.9 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

64
Last Week
0
Last month
Citations as of Sep 22, 2024

Downloads

138
Citations as of Sep 22, 2024

SCOPUSTM   
Citations

6
Citations as of Sep 26, 2024

WEB OF SCIENCETM
Citations

4
Citations as of Sep 26, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.