Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/95384
PIRA download icon_1.1View/Download Full Text
Title: Performance evaluation of a double-pipe heat exchanger fitted with self-rotating twisted tapes
Authors: Zhang, S 
Lu, L 
Dong, C 
Cha, SH
Issue Date: 25-Jul-2019
Source: Applied thermal engineering, 25 July 2019, v. 158, 113770
Abstract: This study presents heat transfer and frication factor characteristics of heat exchanger tube with self-rotating twisted tapes (SRTTs). A comparison of SRTTs and stationary twisted tapes (STTs) as well as an examination of the effects of SRTTs with different twist ratios (Y = 2.2, 3, 4, and 6) on the thermal characteristics were experimentally investigated under turbulence flows (12000 < Re < 45000). The experimental results showed that SRTTs under rotating conditions could enhance the thermal performance of heat exchanger as compared with STTs. The twist ratios were found to have less effect on the initial stages of the rotating behavior, and the SRTTs with lower twisted ratios rotated faster under the same operating conditions. In addition, it was observed that the Nusselt number, pressure drop, and thermal performance factor increased with decreasing twist ratios. The maximum thermal performance factors of 1.03, 0.9444, 0.924, and 0.898 could be achieved at the start of rotating behavior for Y = 2.2, 3, 4, and 6, respectively. Finally, some correlations of the Nusselt number and frication factor were established within ± 10% deviation of the experimental data.
Keywords: Frication factor
Heat transfer enhancement
Self-rotating twisted tapes
Thermal performance factor and Nusselt number
Publisher: Pergamon Press
Journal: Applied thermal engineering 
ISSN: 1359-4311
EISSN: 1873-5606
DOI: 10.1016/j.applthermaleng.2019.113770
Rights: © 2019 Elsevier Ltd. All rights reserved.
© 2019. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Zhang, S., Lu, L., Dong, C., & Cha, S. H. (2019). Performance evaluation of a double-pipe heat exchanger fitted with self-rotating twisted tapes. Applied Thermal Engineering, 158, 113770 is available at https://doi.org/10.1016/j.applthermaleng.2019.113770.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Performance_Evaluation_Double-pipe.pdfPre-Published version1.43 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

107
Last Week
0
Last month
Citations as of Nov 9, 2025

Downloads

146
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

56
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

50
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.