Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/95163
PIRA download icon_1.1View/Download Full Text
Title: Numerical and experimental study on internally cooled liquid desiccant dehumidification concerning film shrinkage shape and vapor condensation
Authors: Wen, T 
Lu, L 
Issue Date: Feb-2019
Source: International journal of thermal sciences, Feb. 2019, v. 136, p. 316-327
Abstract: Falling film has been observed to shrink along its flow direction in a plate dehumidifier. The shrinkage of film reduces the absorption contact area and hence deteriorates the mass transfer performance. Another interesting phenomenon has also been observed, and the condensation of water vapor would occur on the non-wetted area in an internal cooling dehumidifier with a low cooling water temperature. Nevertheless, the film shrinkage and vapor condensation during the dehumidification process were seldom reported. This study developed a new model with the consideration of both the above two factors and phenomena. Besides, a new Sherwood number correlation was proposed based on the experimental data. The influences of different parameters on dehumidification performance were identified. The results indicated that the new model is able to predict the film shrinkage accurately with the average relative wetting ratio difference less than 4%, and the proposed Sherwood number correlation has high prediction accuracy with the mean absolute relative deviation of 7.1%. Then, the weather data of a typical summer day in Hong Kong was chosen to evaluate the influence of vapor condensation. It was found that compared with the situation without condensation, the relative increment of absolute moisture change ranges from 1.2% to 10.7% when concerning vapor condensation. The increment is closely related with the cooling water temperature and air humidity. In the typical summer day, the absolute moisture change has a relative 6.3% increment with the consideration of vapor condensation under certain operating conditions.
Keywords: Empirical correlation
Falling film dehumidifier
Liquid desiccant
Shrinkage
Vapor condensation
Publisher: Elsevier Masson
Journal: International journal of thermal sciences 
ISSN: 1290-0729
DOI: 10.1016/j.ijthermalsci.2018.10.046
Rights: © 2018 Elsevier Masson SAS. All rights reserved.
© 2018. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Wen, T., & Lu, L. (2019). Numerical and experimental study on internally cooled liquid desiccant dehumidification concerning film shrinkage shape and vapor condensation. International Journal of Thermal Sciences, 136, 316-327 is available at https://doi.org/10.1016/j.ijthermalsci.2018.10.046.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Numerical_Experimental_Study.pdfPre-Published version1.54 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

100
Last Week
3
Last month
Citations as of Nov 9, 2025

Downloads

91
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

25
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

24
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.