Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/94274
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Biomedical Engineering-
dc.creatorPang, W-
dc.creatorWang, Y-
dc.creatorGuo, L-
dc.creatorWang, B-
dc.creatorLai, P-
dc.creatorXiao, J-
dc.date.accessioned2022-08-11T02:01:34Z-
dc.date.available2022-08-11T02:01:34Z-
dc.identifier.urihttp://hdl.handle.net/10397/94274-
dc.language.isoenen_US
dc.publisherFrontiers Media SAen_US
dc.rights© 2022 Pang, Wang, Guo, Wang, Lai and Xiao. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.en_US
dc.rightsThe following publication Pang, W., Wang, Y., Guo, L., Wang, B., Lai, P., & Xiao, J. (2022). Two-Dimensional Photoacoustic/Ultrasonic Endoscopic Imaging Based on a Line-Focused Transducer. Frontiers in Bioengineering and Biotechnology, 9, 807633 is available at https://doi.org/10.3389/fbioe.2021.807633en_US
dc.subjectAcoustic resolution photoacoustic/ultrasonic endoscopy (PA/USE)en_US
dc.subjectImaging depth of fielden_US
dc.subjectImproved back-projection imaging algorithmen_US
dc.subjectLine-focused transduceren_US
dc.subjectPhotoacoustic imaging (PAI)en_US
dc.subjectUltrasonic imaging (USI)en_US
dc.titleTwo-dimensional photoacoustic/ultrasonic endoscopic imaging based on a line-focused transduceren_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume9-
dc.identifier.doi10.3389/fbioe.2021.807633-
dcterms.abstractExisting acoustic-resolution photoacoustic/ultrasonic endoscopy (PA/USE) generally employs a point-focused transducer for ultrasound detection, which is only sensitive in its focal region, thus the lateral resolution and sensitivity drop dramatically when the targets move far from its focus. Even if a dynamic focusing algorithm is applied, the sensitivity out of the transducer focus is still much lower than that in the focus in ultrasonic imaging mode. In this work, we propose an acoustic-resolution PA/USE with a line-focused transducer to realize automatic focusing for the first time. In comparison to a point-focused transducer, the line-focused transducer emits a more uniform sound field, causing the original signal intensity and signal-to-noise ratio (SNR) of the front and rear targets to be closer in the radial direction, which is beneficial for improving target signal uniformity in ultrasonic imaging. Simultaneously, we improved the resolution of the defocus area by modifying a prior work of back-projection (BP) reconstruction algorithm typically used in point-focused transducer based PAE and applying it to line-focused PA/USE. This combined approach may significantly enhance the depth of field of ultrasonic imaging and the resolution of the defocus zone in PA/US imaging, compared to the conventional method. Sufficient numerical simulations and phantom experiments were performed to verify this method. The results show that our method can effectively improve the lateral resolution in the image’s defocused region to achieve automatic focusing and perfectly solve the defect of the target signal difference in the far-focus region in ultrasonic imaging, while also enhancing the image SNR and contrast. The proposed method in this paper lays foundations for the realization of photoacoustic/ultrasonic combined endoscopy with enhanced lateral resolution and depth of field, which can potentially benefit a many of biomedical applications.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationFrontiers in bioengineering and biotechnology, Jan. 2022, v. 9, 807633-
dcterms.isPartOfFrontiers in bioengineering and biotechnology-
dcterms.issued2022-01-
dc.identifier.scopus2-s2.0-85123212409-
dc.identifier.eissn2296-4185-
dc.identifier.artn807633-
dc.description.validate202208 bckw-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumbera1564en_US
dc.identifier.SubFormID45435en_US
dc.description.fundingSourceRGCen_US
dc.description.fundingSourceOthersen_US
dc.description.fundingTextNational Natural Science Foundation of China; Guangdong Science and Technology Commission; Hong Kong Innovation and Technology Commissionen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
fbioe-09-807633.pdf2.4 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

55
Last Week
1
Last month
Citations as of May 12, 2024

Downloads

28
Citations as of May 12, 2024

SCOPUSTM   
Citations

3
Citations as of May 16, 2024

WEB OF SCIENCETM
Citations

2
Citations as of May 16, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.