Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/94051
PIRA download icon_1.1View/Download Full Text
Title: Enhancing ultrasound transmission and focusing through a stiff plate with inversely optimized auxiliary meta-lens
Authors: Gao, H 
Gu, Z 
Liang, S
Liu, T 
Zhu, J
Su, Z 
Issue Date: 14-Mar-2022
Source: Applied physics letters, 14 Mar. 2022, v. 120, no. 11, 111701
Abstract: Effective sound energy transmission and beam manipulation through stiff and dense materials such as metal remain daunting tasks. It is in part attributable to the vast impedance mismatch between those materials and ambient media. Adding openings may facilitate to better bridge energy over, yet ineffective in many applications and may also damage the structural integrity. Here, we present an auxiliary ultrasound focusing meta-lens for stiff and dense materials. It offers significantly enhanced ultrasound transmission and focusing through a stiff metal plate yet without enforcing any through holes or openings. The simple, one-sided only meta-structures are designed and optimized by an inverse strategy based on the genetic algorithm. We numerically and experimentally demonstrate the much enhanced ultrasound transmission when the meta-lens is added to a flat brass plate, along with the capability to offer simultaneous ultrasound focusing. This design methodology can be easily extended to deal with more complex shaped target in a straightforward manner, offering a practical solution to the efficient tunneling of ultrasound energy through stiff and dense materials. With simple grating structures, the meta-lens can be easily fabricated, showing great application prospects in medical imaging and disease treatment.
Publisher: American Institute of Physics
Journal: Applied physics letters 
ISSN: 0003-6951
EISSN: 1077-3118
DOI: 10.1063/5.0085462
Rights: © 2022 Author(s). Published under an exclusive license by AIP Publishing.
This article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in He Gao, Zhongming Gu, Shanjun Liang, Tuo Liu, Jie Zhu, and Zhongqing Su, "Enhancing ultrasound transmission and focusing through a stiff plate with inversely optimized auxiliary meta-lens", Appl. Phys. Lett. 120, 111701 (2022) and may be found at https://dx.doi.org/10.1063/5.0085462.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
111701_1_online.pdf1.81 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

65
Last Week
1
Last month
Citations as of May 5, 2024

Downloads

98
Citations as of May 5, 2024

SCOPUSTM   
Citations

10
Citations as of Apr 26, 2024

WEB OF SCIENCETM
Citations

7
Citations as of May 2, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.