Abstract: The control performance of a streamwise-oriented dielectric barrier discharge (DBD) plasma actuator, a set of plasma streamwise vortex generators (PSVGs), and a hybrid actuator of the plasma actuator and PSVGs on the reduction in bluff body flow separation, vortex-induced vibration (VIV), and wake fluctuation is experimentally investigated. Experiments are conducted in a low-speed and low-turbulence wind tunnel with a Reynolds number between 3 ×103 and 1.2 ×104 based on the diameter of a half circular cylinder. Particle image velocimetry (PIV) is used to obtain details on the flow fields over a short D-shaped bluff body. Force measurement is conducted to compare the reduction in drag and vibration oscillations using these three types of plasma actuators. The PIV flow fields show that all of the plasma actuators suppress the flow separation on the bluff body, narrow the size of the wake, and decrease the turbulence kinetic energy (TKE) level in the wake. This stable controlled vortex shedding system can reduce the effect of the natural frequency of the bending stiffness-dominated cylinder structure system, thus avoiding the occurrence of resonance in advance. The reduction in drag and lateral lift oscillation are studied by mapping the changes in force coefficients and fluctuations as a function of Reynolds number. A comparison of these plasma actuators shows that the hybrid actuator achieves best drag reduction, suppression of lift oscillation, and Kármán vortex shedding in the wake at low speed, because three-dimensional flow structures are generated on the surface of the bluff body that consequently enhance the mixing. The results suggest that PSVGs and ameliorative actuators are promising for wake flow control in bluff bodies at low speeds.
Keywords: D-shaped bluff body
DBD
Drag reduction
Flow control
VIV
Publisher: Academic Press
Journal: Journal of fluids and structures 
ISSN: 0889-9746
EISSN: 1095-8622
DOI: 10.1016/j.jfluidstructs.2021.103292
Rights: © 2021 Elsevier Ltd. All rights reserved.
©2021. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Chen, Z., & Wen, C. Y. (2021). Flow control of a D-shaped bluff body using different DBD plasma actuators. Journal of Fluids and Structures, 103, 103292 is available at https://doi.org/10.1016/j.jfluidstructs.2021.103292.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Chen_Flow_Control_D-Shaped.pdfPre-Published version67.08 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

37
Last Week
0
Last month
Citations as of May 5, 2024

Downloads

23
Citations as of May 5, 2024

SCOPUSTM   
Citations

10
Citations as of Apr 26, 2024

WEB OF SCIENCETM
Citations

8
Citations as of May 2, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.