DC FieldValueLanguage
dc.contributorDepartment of Electronic and Information Engineering-
dc.creatorHuang, Z-
dc.creatorWong, SC-
dc.creatorTse, CK-
dc.date.accessioned2022-03-22T06:30:49Z-
dc.date.available2022-03-22T06:30:49Z-
dc.identifier.issn0885-8993-
dc.identifier.urihttp://hdl.handle.net/10397/92332-
dc.language.isoenen_US
dc.publisherInstitute of Electrical and Electronics Engineersen_US
dc.rights© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.en_US
dc.rightsThe following publication Z. Huang, S. -C. Wong and C. K. Tse, "Comparison of Basic Inductive Power Transfer Systems With Linear Control Achieving Optimized Efficiency," in IEEE Transactions on Power Electronics, vol. 35, no. 3, pp. 3276-3286, March 2020 is available at https://doi.org/10.1109/TPEL.2019.2932100.en_US
dc.subjectComparisonen_US
dc.subjectInductive power transfer (IPT)en_US
dc.subjectLinear controlen_US
dc.subjectOptimized efficiencyen_US
dc.titleComparison of basic inductive power transfer systems with linear control achieving optimized efficiencyen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage3276-
dc.identifier.epage3286-
dc.identifier.volume35-
dc.identifier.issue3-
dc.identifier.doi10.1109/TPEL.2019.2932100-
dcterms.abstractInductive power transfer (IPT) systems with front-side and load-side converters are generally developed for better overall system efficiency than a single IPT converter by providing maximum efficiency tracking and output regulation against variations of coupling coefficient (k) and load. The optimum efficiency point of an IPT converter is at a particular loading resistance, which varies with k and is hard to measure directly for the purpose of control. Perturb and observe control is normally implemented to iteratively track the optimum efficiency point. However, this heuristic algorithm results in slow response to the variations of k and load. Recently, a much faster linear control for optimum efficiency tracking has been developed for the series-series (SS) IPT system only. This paper proposes a general linear control scheme for all four basic IPT systems to track the optimum efficiency point. Unlike the SS IPT converter, it is found that additional control of either frequency or adaptive compensation is needed for the other three basic IPT converters to operate against the variation of k. Different input to output transfer functions and their k- and load-independent properties at optimum efficiency are identified for all four basic IPT systems. Thus, a general fast linear control can be applied in the front-side converter to achieve optimum efficiency, while the load-side converter regulates the output power independently. Furthermore, the maximum efficiencies of the IPT converters with these four basic compensations for an identical loosely-coupled transformer are compared theoretically and verified experimentally. The parallel-parallel IPT converter gives the best efficiency. Its additional frequency control in conjunction with the optimum efficiency tracking and the output power regulation is also experimentally validated.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationIEEE transactions on power electronics, Mar. 2020, v. 35, no. 3, 8782641, p. 3276-3286-
dcterms.isPartOfIEEE transactions on power electronics-
dcterms.issued2020-03-
dc.identifier.scopus2-s2.0-85077216981-
dc.identifier.eissn1941-0107-
dc.identifier.artn8782641-
dc.description.validate202203 bchy-
dc.description.oaAccepted Manuscripten_US
dc.identifier.FolderNumberRGC-B1-014en_US
dc.description.fundingSourceRGCen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Huang_Comparisbasic_Inductive_Power.pdfPre-Published version3.75 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

46
Last Week
0
Last month
Citations as of May 12, 2024

Downloads

60
Citations as of May 12, 2024

SCOPUSTM   
Citations

26
Citations as of May 16, 2024

WEB OF SCIENCETM
Citations

22
Citations as of May 16, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.