Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/89511
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineeringen_US
dc.contributorDepartment of Building Services Engineeringen_US
dc.contributorResearch Institute for Sustainable Urban Developmenten_US
dc.creatorXiong, Cen_US
dc.creatorLiu, Yen_US
dc.creatorXu, Cen_US
dc.creatorHuang, Xen_US
dc.date.accessioned2021-04-09T08:50:13Z-
dc.date.available2021-04-09T08:50:13Z-
dc.identifier.issn0379-7112en_US
dc.identifier.urihttp://hdl.handle.net/10397/89511-
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.rights© 2020 Elsevier Ltd. All rights reserved.en_US
dc.rights© 2020. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/.en_US
dc.rightsThe following publication Xiong, C., Liu, Y., Xu, C., & Huang, X. (2021). Extinguishing the dripping flame by acoustic wave. Fire Safety Journal, 120, 103109 is available at https://dx.doi.org/10.1016/j.firesaf.2020.103109.en_US
dc.subjectAcoustic effecten_US
dc.subjectCandle flameen_US
dc.subjectExtinctionen_US
dc.subjectFire suppressionen_US
dc.subjectMoving flameen_US
dc.subjectPolyethyleneen_US
dc.titleExtinguishing the dripping flame by acoustic waveen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.volume120en_US
dc.identifier.doi10.1016/j.firesaf.2020.103109en_US
dcterms.abstractDripping of molten fuels is a widely observed phenomenon in the wire fire and façade fire, which promotes the fire spread and increases the fire hazard. The flame attachment to drip is a necessary condition for dripping ignition, so that extinguishing the dripping flame can effectively reduce the dripping fire hazard. In this work, we investigated the use of acoustic wave to extinguish the fast-moving dripping flame. Continuous drips, with a mass of 6.2 mg and a diameter of 2.6 mm, were produced from a burning polyethylene tube, and two fall heights, 0.3 m and 0.7 m with velocities of about 2 m/s and 3 m/s, were selected as the targets. The sound source varied in pressure from 80 to 114 dB and frequency from 90 to 110 Hz. Results showed that the effectiveness of flame extinction by acoustic wave decreases as the dripping velocity increases, so the acoustic wave is more effective to extinguish the dripping flame in the early stage. An extinction criterion was formulated based on a characterized Damköhler number to describe the underlying mechanism. This work provides important information on the acoustic effect on a moving flame and helps mitigate the fire hazard of dripping phenomena.en_US
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationFire safety journal, Mar. 2021, v. 120, 103109en_US
dcterms.isPartOfFire safety journalen_US
dcterms.issued2021-03-
dc.identifier.scopus2-s2.0-85086912772-
dc.identifier.artn103109en_US
dc.description.validate202104 bcvcen_US
dc.description.oaAccepted Manuscripten_US
dc.identifier.FolderNumbera0685-n17-
dc.identifier.SubFormID1002-
dc.description.fundingSourceSelf-fundeden_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
FSJ-IAFSS_2020_sound_suppress_drip.pdfPre-Published version1.85 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

57
Last Week
1
Last month
Citations as of May 12, 2024

Downloads

49
Citations as of May 12, 2024

SCOPUSTM   
Citations

21
Citations as of May 16, 2024

WEB OF SCIENCETM
Citations

13
Citations as of May 16, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.