| Title: | Utilization of earth-to-air heat exchanger to pre-cool/heat ventilation air and its annual energy performance evaluation : a case study | Authors: | Zhang, C Wang, J Li, L Wang, F Gang, W |
Issue Date: | 2-Oct-2020 | Source: | Sustainability, 2 Oct. 2020, v. 12, no. 20, 8330, p. 1-17 | Abstract: | An earth-to-air heat exchanger (EAHE) system utilizes the low-grade thermal energy of underground soil to warm up and cool down the flowing air within an underground buried pipe. Integrating the EAHE system with building ventilation can reduce the energy demand for conditioning ventilation air. The main purposes of this paper are to estimate the year-round energy-saving potential of the EAHE-assisted building ventilation system and provide its design guidelines in a hot-summer and cold-winter climate. A steady-state heat transfer model was proposed to calculate the outlet air temperature of an EAHE and further identify its ability to preheat and precool ventilation air. Influences of depth, length, and diameter of a buried pipe on the year-round thermal performance of the EAHE system were evaluated. The results show that considering the compromise between thermal performance and construction costs of the EAHE system, a depth of 5 m and a length of 80 m are recommended. The EAHE system can provide a mean daily cooling and heating capacity of 19.6 kWh and 19.3 kWh, respectively. Moreover, the utilization of the EAHE system can reduce by 16.0% and 50.1% the energy demand for cooling and heating ventilation air throughout the whole year. | Keywords: | Building energy efficiency Building ventilation Earth-To-Air heat exchanger Renewable energy Sustainable building |
Publisher: | Molecular Diversity Preservation International (MDPI) | Journal: | Sustainability | EISSN: | 2071-1050 | DOI: | 10.3390/su12208330 | Rights: | © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). The following publication Zhang, C.; Wang, J.; Li, L.; Wang, F.; Gang, W. Utilization of Earth-to-Air Heat Exchanger to Pre-Cool/Heat Ventilation Air and Its Annual Energy Performance Evaluation: A Case Study. Sustainability 2020, 12, 8330 is available at https://dx.doi.org/10.3390/su12208330 |
| Appears in Collections: | Journal/Magazine Article |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| Zhang_Utilization_Earth-To-Air_Heat.pdf | 4.52 MB | Adobe PDF | View/Open |
Page views
98
Last Week
1
1
Last month
Citations as of Nov 9, 2025
Downloads
166
Citations as of Nov 9, 2025
SCOPUSTM
Citations
22
Citations as of Dec 19, 2025
WEB OF SCIENCETM
Citations
16
Citations as of Dec 18, 2025
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.