Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/88777
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Biomedical Engineering-
dc.contributorChinese Mainland Affairs Office-
dc.creatorNi, M-
dc.creatorZhang, FF-
dc.creatorMei, J-
dc.creatorLin, CYJ-
dc.creatorGruber, SMS-
dc.creatorNiu, WX-
dc.creatorWong, DWC-
dc.creatorZhang, M-
dc.date.accessioned2020-12-22T01:07:50Z-
dc.date.available2020-12-22T01:07:50Z-
dc.identifier.issn1792-0981-
dc.identifier.urihttp://hdl.handle.net/10397/88777-
dc.language.isoenen_US
dc.publisherSpandidos Publicationsen_US
dc.rights© Ni et al. This is an open access article distributed under the terms of Creative Commons Attribution License(https://creativecommons.org/licenses/by-nc-nd/4.0/).en_US
dc.rightsThe following publication Ni, M., Zhang, F. F., Mei, J., Lin, C. Y. J., Gruber, S. M. S., Niu, W. X., . . . Zhang, M. (2020). Biomechanical analysis of four augmented fixations of plate osteosynthesis for comminuted mid-shaft clavicle fracture: A finite element approach. Experimental and Therapeutic Medicine, 20(3), 2106-2112 is available at https://dx.doi.org/10.3892/etm.2020.8898en_US
dc.subjectClavicle fractureen_US
dc.subjectInternal fixationen_US
dc.subjectPlateen_US
dc.subjectInterfragmentary screwen_US
dc.subjectCerclage wiringen_US
dc.subjectBiomechanicsen_US
dc.subjectFinite element simulationen_US
dc.titleBiomechanical analysis of four augmented fixations of plate osteosynthesis for comminuted mid-shaft clavicle fracture : a finite element approachen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage2106-
dc.identifier.epage2112-
dc.identifier.volume20-
dc.identifier.issue3-
dc.identifier.doi10.3892/etm.2020.8898-
dcterms.abstractSufficient stabilization of comminuted mid-shaft clavicle fractures via plate fixation is difficult to achieve. Various augmentations, including interfragmentary screws and cerclage wiring, have been adopted to reinforce fixation stability. The present study aimed to assess the biomechanical stability of augmented plate fixations using the finite element method. First, a clavicle fracture model was created from CT data. Fixation was then induced using a locking compressive plate (LCP) with the following four augmentations: i) Double inner cerclage wirings (DICW), ii) double outer cerclage wirings (DOCW), iii) a single interfragmentary screw (SIS) and iv) double interfragmentary screws (DIS). Compressive and bending forces of 100 N were subsequently applied at the acromial region of the clavicle. The stress distribution, displacement and fracture micro-motions of the model were assessed and compared. The DOCW resulted in the highest stress exerted on the LCP, followed by SIS, DICW and DIS. For the clavicle fracture, DICW, DOCW and SIS resulted in high stress levels. However, DIS fixation alone resulted in levels of stress that were below the yield strength of cortical bone. Displacement analysis revealed that DOCW fixation resulted in the greatest degree of displacement and fracture micro-motions, followed by SIS, DICW and DIS. The results indicated that SIS, DIS and DOCW may be used as augmentations of LCP fixation for comminuted mid-shaft clavicle fractures. However, DIS was the recommended augmentation due to it exerting the lowest stress and the highest stability compared with the other fixations. The DICW may be used to aid fracture reduction and plate placement in surgery but should be avoided for permanent fixation.-
dcterms.accessRightsopen accessen_US
dcterms.bibliographicCitationExperimental and therapeutic medicine, Sept. 2020, v. 20, no. 3, p. 2106-2112-
dcterms.isPartOfExperimental and therapeutic medicine-
dcterms.issued2020-09-
dc.identifier.isiWOS:000563844300032-
dc.identifier.pmid32765684-
dc.identifier.eissn1792-1015-
dc.description.validate202012 bcrc-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_Scopus/WOSen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
Ni_Biomechanical_Four_Augmented.pdf844.63 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

68
Last Week
0
Last month
Citations as of May 19, 2024

Downloads

17
Citations as of May 19, 2024

WEB OF SCIENCETM
Citations

3
Last Week
0
Last month
Citations as of May 16, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.