Title: Inhibition of in-stent restenosis after graphene oxide double-layer drug coating with good biocompatibility
Authors: Ge, S
Xi, YD
Du, RL
Ren, YZ
Xu, ZC
Tan, YH 
Wang, YZ
Yin, TY
Wang, GX
Issue Date: 2019
Source: Regenerative biomaterials, Oct. 2019, v. 6, no. 5, p. 299-309
Abstract: In this study, we designed a double layer-coated vascular stent of 316L stainless steel using an ultrasonic spray system to achieve both antiproliferation and antithrombosis. The coating included an inner layer of graphene oxide (GO) loaded with docetaxel (DTX) and an outer layer of carboxymethyl chitosan (CMC) loaded with heparin (Hep). The coated surface was uniform without aggregation and shedding phenomena before and after stent expanded. The coating treatment was able to inhibit the adhesion and activation of platelets and the proliferation and migration of smooth muscle cells, indicating the excellent biocompatibility and antiproliferation ability. The toxicity tests showed that the GO/DTX and CMC/Hep coating did not cause deformity and organ abnormalities in zebrafish under stereomicroscope. The stents with GO double-layer coating were safe and could effectively prevent thrombosis and in-stent restenosis after the implantation into rabbit carotid arteries for 4-12 weeks.
Keywords: Graphene oxide
Drug coating
Vascular stents
Restenosis
Thrombosis
Publisher: Oxford University Press
Journal: Regenerative biomaterials 
ISSN: 2056-3418
EISSN: 2056-3426
DOI: 10.1093/rb/rbz010
Rights: © The Author(s) 2019. Published by Oxford University Press.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
The following publication Shuang Ge, Yadong Xi, Ruolin Du, Yuzhen Ren, Zichen Xu, Youhua Tan, Yazhou Wang, Tieying Yin, Guixue Wang, Inhibition of in-stent restenosis after graphene oxide double-layer drug coating with good biocompatibility, Regenerative Biomaterials, Volume 6, Issue 5, October 2019, Pages 299–309 is available at https://dx.doi.org/10.1093/rb/rbz010
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Ge_Inhibition_In-stent_Restenosis.pdf1.63 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

96
Last Week
4
Last month
Citations as of Nov 9, 2025

Downloads

42
Citations as of Nov 9, 2025

SCOPUSTM   
Citations

36
Citations as of Dec 19, 2025

WEB OF SCIENCETM
Citations

34
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.