Title: Pilot testing of Assessment of Capacity for Myoelectric Control (ACMC) in evaluating myoelectric hand function in Chinese population
Authors: Lai, FH 
Yan, EW 
Ma, BT 
Zhao, ZG 
Liu, T 
Issue Date: 2019
Source: Annals of physiotherapy & occupational therapy, 2019, v. 2, no. 1, p. 1-9
Abstract: Upper limb amputations cause marked functional disability and lower the individual’s self-body image, with severe psychological implications. Many rehabilitation parameters are involved in the successful rehabilitation of upper limb amputations. The aim of this study was to examine the validity and reliability of the Chinese version of Assessment of Capacity for Myoelectric Control (Chinese-ACMC) in upper limb amputated subjects and with a myo-electric-powered prosthetic hand.
To validate the Chinese version of Assessment of Capacity for Myoelectric Control (Chinese-ACMC) in upper limb amputee subjects (children and adults) with a myo-electric-powered prosthetic hand. A sample of convenience sampling of 22 subjects (11 males, 11 females) with upper limb amputation and myoelectric prosthetic hands were recorded during a regular clinical visit for ACMC. Each subject was evaluated according to four criteria: (a) Upper Limb Amputation including all levels of amputation; (b) No specific pain type – no matter phantom or pain in the stump; (c) With intact cognitive function; (d) Age ranged from 12 to 40 years. With instruction, occupational therapists and prosthetic-orthotics with at least twenty years’ clinical experience of myoelectric prosthesis training would conduct the 30-items Chinese ACMC for each subject. A serial of errand tasks of activities of daily living were designed for evaluation. Individuals’ ratings were repeated after 4 weeks. Through test-retest reliability, internal consistency testing, factor analysis, intra and inter factor correlation analysis. A four-factor structure, namely, “Gripping”, “Holding”, “Releasing” and “Coordinating” are identified.
Publisher: Medwin Publishers
Journal: Annals of physiotherapy & occupational therapy 
EISSN: 2196-419X
Rights: Copyright© Lai FH, et al.
Creative Commons Attribution 4.0 International (CC BY 4.0)(https://creativecommons.org/licenses/by/4.0/)
The following publication Lai FH, et al. Pilot Testing of Assessment of Capacity for Myoelectric Control (ACMC) in Evaluating Myoelectric Hand Function in Chinese Population. Ann Physiother Occup Ther 2019, 2(1): 000114 is available at https://medwinpublishers.com/APhOT/volume.php?volumeId=180&issueId=582
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Lai_ACMC_Myoelectric_Hand.pdf753.98 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

49
Last Week
0
Last month
Citations as of Apr 28, 2024

Downloads

19
Citations as of Apr 28, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.