Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/87539
PIRA download icon_1.1View/Download Full Text
Title: Multiple scan averaging to yield accurate quantitative analysis of optical coherence tomography angiograms
Authors: Khan, HM
Gentle, A
Armitage, JA
To, CH 
Lam, AKC 
Issue Date: 2020
Source: Scientific reports, 2020, v. 10, no. 1, 6194
Abstract: Optical coherence tomography angiography (OCTA) is widely used in ophthalmic practice. Most OCTA studies based their findings on a single OCTA measurement. We conducted an observational study of 82 eyes from 82 healthy subjects to compare variations of OCTA parameters among five successive measurements. A 3 × 3 mm Early Treatment of Diabetic Retinopathy Study grid centred at fovea was used. An average from five successive OCTA measurements (both perfusion density and vessel density) was calculated to be used as the reference standard. There was no significant difference in perfusion and vessel densities among five successive OCTA measurements, and from different levels of averaging. Perfusion density was close to the reference standard when average from three measurements was used (discrepancy within 1.5%) as compared with using just one measurement (discrepancy from 3.2% to 4.5%). Vessel density was also close to reference standard when average from three measurements was used (within 0.8 mm−1) as compared with using just one measurement (2 mm−1). Software feature that allows OCTA devices to average quantitative parameters for analysis will be useful.
Publisher: Nature Publishing Group
Journal: Scientific reports 
EISSN: 2045-2322
DOI: 10.1038/s41598-020-62956-2
Rights: © Te Author(s) 2020. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. Te images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
The following publication Khan, H.M., Gentle, A., Armitage, J.A. et al. Multiple scan averaging to yield accurate quantitative analysis of optical coherence tomography angiograms. Sci Rep 10, 6194 (2020), is available at https://doi.org/10.1038/s41598-020-62956-2
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Khan_Multiple_scan_averaging.pdf1.61 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

52
Last Week
0
Last month
Citations as of May 5, 2024

Downloads

23
Citations as of May 5, 2024

SCOPUSTM   
Citations

7
Citations as of Apr 5, 2024

WEB OF SCIENCETM
Citations

6
Citations as of May 2, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.