Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/74615
PIRA download icon_1.1View/Download Full Text
Title: Acoustic performance of different Helmholtz resonator array configurations
Authors: Cai, C 
Mak, CM 
Issue Date: 15-Jan-2018
Source: Applied acoustics, 15 Jan. 2018, v. 130, p. 204-209
Abstract: This paper presents a theoretical study of the acoustic performance of different Helmholtz resonator (HR) array configurations. A dual HR consisting of two HRs connected in series (neck-cavity-neck-cavity) could be considered as a serial HR array. Two HRs mounted on the same cross-section of the duct constitute a parallel HR array. A lined HR array is composed of two HRs installed on the longitudinal direction of the duct. Since HR is reactive silencer without energy consumption, the energy storage capacity (CTL) of HR arrays could be defined as the area under transmission loss curve. The transfer matrix method is developed to conduct the investigation. The predicted theoretical results fit well with the Finite Element Method (FEM) simulation results. The results indicate that the installation methods have significant effects on transmission loss curves. However, the CTL of the dual HR equals the CTL of each single component HR mounted on the duct in despite of the dual HR having two HRs. The CTL of the parallel HR array is equivalent to the CTL of the lined HR array, which is twice the CTL of the dual HR. The CTL should therefore be considered as one of the main acoustic characteristics of a HR or an array and be taken into consideration in noise control optimization and HR design.
Keywords: Energy storage capacity
Helmholtz resonator
Transmission loss
Publisher: Pergamon Press
Journal: Applied acoustics 
ISSN: 0003-682X
EISSN: 1872-910X
DOI: 10.1016/j.apacoust.2017.09.026
Rights: © 2017 Elsevier Ltd. All rights reserved.
© 2017. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
The following publication Cai, C., & Mak, C. M. (2018). Acoustic performance of different Helmholtz resonator array configurations. Applied Acoustics, 130, 204-209 is available at https://doi.org/10.1016/j.apacoust.2017.09.026.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Acoustic_Performance_Different.pdfPre-Published version890.2 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

181
Last Week
0
Last month
Citations as of Apr 21, 2024

Downloads

97
Citations as of Apr 21, 2024

SCOPUSTM   
Citations

69
Last Week
0
Last month
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

53
Last Week
0
Last month
Citations as of Apr 25, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.