Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/73851
PIRA download icon_1.1View/Download Full Text
Title: Biomechanical consequences of subtalar joint arthroereisis in treating posterior tibial tendon dysfunction : a theoretical analysis using finite element analysis
Authors: Wong, DWC 
Wang, Y 
Chen, TLW 
Leung, AKL 
Zhang, M 
Issue Date: 2017
Source: Computer methods in biomechanics and biomedical engineering, 2017, v. 20, no. 14, p. 1525-1532
Abstract: Subtalar joint arthroereisis (SJA) has been introduced to control the hyperpronation in cases of flatfoot. The objective of this study is to evaluate the biomechanical consequence of SJA to restore the internal stress and load transfer to the intact state from the attenuated biomechanical condition induced by posterior tibial tendon dysfunction (PTTD). A three-dimensional finite element model of the foot and ankle complex was constructed based on clinical images of a healthy female (age 28 years, height 165 cm, body mass 54 kg). The boundary and loading condition during walking was acquired from the gait experiment of the model subject. Five sets of simulations (conditions) were completed: intact condition, mild PTTD, severe PTTD, mild PTTD with SJA, severe PTTD with SJA. The maximum von Mises stress of the metatarsal shafts and the load transfer along the midfoot during stance were analyzed. Generally, SJA deteriorated the joint force of the medial cuneonavicular and calcaneocuboid joints during late stance, while that of the metatarsocuneiform joints during early stance were over-corrected. Only the calcaneocuboid joint force at 45% stance demonstrated a trend of improvement. Besides, SJA exaggerated the increased stress of the metatarsals compared to the PTTD conditions, except that of the first metatarsal. Our study did not support the hypothesis that SJA can restore the internal load transfer and midfoot stress. SJA cannot compensate the salvage of midfoot stability attributed by PTTD and could be biomechanically insufficient to restore the biomechanical environment. Additional procedures such as orthotic intervention may be necessary.
Keywords: Extra-osseous talotarsal stabilization
Flatfoot
Pes planus
Posterior tibial tendon dysfunction
Sinus tarsi implant
Talotarsal mechanism
Publisher: Routledge, Taylor & Francis Group
Journal: Computer methods in biomechanics and biomedical engineering 
ISSN: 1025-5842
EISSN: 1476-8259
DOI: 10.1080/10255842.2017.1382484
Rights: © 2017 Informa UK Limited, trading as Taylor & Francis Group
This is an Accepted Manuscript of an article published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering on 27 Sept. 2017 (published online), available at: http://www.tandfonline.com/10.1080/10255842.2017.1382484
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Leung_Biomechanical_Consequences_Subtalar.pdfPre-Published version723.61 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

120
Last Week
0
Last month
Citations as of Apr 14, 2024

Downloads

96
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

18
Last Week
0
Last month
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

13
Last Week
0
Last month
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.