Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/72820
Title: Reduction of physiological strain under a hot and humid environment by a hybrid cooling vest
Authors: Chan, APC 
Yang, Y 
Wong, FKW 
Yam, MCH 
Wong, DP
Song, WF
Keywords: Effect size
Physiological strain
Training conditions
Issue Date: 2017
Publisher: Lippincott Williams & Wilkins
Source: Journal of strength and conditioning research, Feb 2017, Publish Ahead of Print, DOI: 10.1519/JSC.0000000000001837 How to cite?
Journal: Journal of strength and conditioning research 
Abstract: Cooling treatment is regarded as one of good practices to provide safe training conditions to athletic trainers in the hot environment. The present study aimed to investigate whether wearing a commercial lightweight and portable hybrid cooling vest that combines air ventilation fans with frozen gel packs was an effective means to reduce participants’ body heat strain. In this within-subject repeated measures study, 10 male volunteers participated in two heat-stress trials (one with the cooling vest – COOL condition, and another without – CON condition, in a randomized order) inside a climatic chamber with a controlled ambient temperature 33 °C and relative humidity (RH) 75% on an experimental day. Each trial included a progressively incremental running test, followed by a 40 min post-exercise recovery. Core temperature (Tc), heart rate (HR), sweat rate, rating of perceived exertion (RPE), exercise duration, running distance, power output, and sweat rate were measured. When comparing the two conditions, a non-statistically significant moderate cooling effect in rate of increase in Tc (0.03±0.02 °C/min for COOL vs. 0.04±0.02 °C/min for CON, p=0.054, d=0.57), HR (3±1 bpm/min for COOL vs. 4±1 bpm/min for CON, p=0.229, d=0.40), and physiological strain index (PSI) (0.20±0.06 unit/min for COOL vs. 0.23±0.06 unit/min for CON, p=0.072, d=0.50) was found in the COOL condition during exercise. A non-statistically significant (p>0.05) trivial cooling effect (d<0.2) was observed between the COOL and CON conditions for measures of exercise duration, running distance, power output, sweat rate and RPE. It is concluded that the use of the hybrid cooling vest achieved a moderate cooling effect in lowering the rate of increase in physiological strain without impeding the performance of progressively incremental exercise in the heat.
URI: http://hdl.handle.net/10397/72820
ISSN: 1064-8011
DOI: 10.1519/JSC.0000000000001837
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page view(s)

317
Last Week
3
Last month
Citations as of Oct 14, 2018

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.