Title: Optimum design of PV/Wind hybrid system II. A case study
Other Title: 风光互补发电系统的优化设计Ⅱ匹配设计实例
Authors: Ai, B
Yang, HX 
Shen, H
Liao, X
Issue Date: 2003
Source: 太阳能学报 (Acta energiae solaris sinica), 2003, v. 24, no. 5, p. 718-723
Abstract: 根据风光互补发电系统优化设计的CAD方法编制了相应的匹配计算程序,并把该程序应用于一假定安装在香港横澜岛上的风光互补发电系统的优化设计。利用香港天文台提供的1989年全年每小时实测的太阳辐射、风速和温度数据以及全年负载用电分布等数据给出了满足两种供电可靠性要求即全年功率供给亏欠率LPSP分别等于0 1和0 01的优化了的系统配置。文章还比较并讨论了这两种优化的系统配置每小时、每日、每月和全年的性能表现。
According to the CAD method for optimum sizing of PV/wind hybrid system a set of match calculation programs has been developed.Applying these match calculation programs to an assumed PV/wind hybrid system to be installed at Waglan island of Hong Kong,two optimum configurations which correspond to LPSP values equal to 0.1 and 0.01 respectively were given based on load demand and hourly solar radiation,wind speed and temperature data measured by Hong Kong Observatory in 1989.Hourly,daily,monthly and yearly performances of the two optimum configurations are also compared in this paper.
Keywords: PV/wind hybrid system
Optimum sizing
CAD method
Publisher: 中國太陽能學會
Journal: 太阳能学报 (Acta energiae solaris sinica) 
ISSN: 0254-0096
Rights: © 2003 中国学术期刊电子杂志出版社。本内容的使用仅限于教育、科研之目的。
© 2003 China Academic Journal Electronic Publishing House. It is to be used strictly for educational and research purposes.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
r18995.pdf198.36 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

67
Last Week
0
Last month
Citations as of Apr 21, 2024

Downloads

74
Citations as of Apr 21, 2024

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.