Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/6552
PIRA download icon_1.1View/Download Full Text
Title: Economic analysis of a solid oxide fuel cell cogeneration/trigeneration system for hotels in Hong Kong
Authors: Chen, JMP
Ni, M 
Issue Date: Jun-2014
Source: Energy and buildings, June 2014, v. 75, p. 160-169
Abstract: Solid oxide fuel cell (SOFC) is promising for efficient stationary power generation. The high temperature waste heat from SOFC stack can be recovered for cogeneration/trigeneration. Due to the lack of relevant analysis on SOFC system in Hong Kong, this research is purposely designed to investigate the economics of a SOFC-absorption cooling cogeneration/trigeneration system for building application in Hong Kong. Energy consumption profile of Hotel ICON is adopted for a case study. Existing products of SOFC server and absorption chiller are chosen to configure the system. It is found that the payback period is less than 6 years with the Government subsidy at 50% of the overall system cost for a trigeneration system. Sensitivity analyses show that increases in the rate of electricity and the level of government subsidy increase the payback period of SOFC systems in Hong Kong. Besides certain technological difficulties, obstacles on the way to realize the proposed cogeneration/trigeneration system in Hong Kong are legal and social constraints and space limitation as well. This study highlights the suitability and the environmental impact of the SOFC-based multi-generation for building application in Hong Kong.
Keywords: Solid oxide fuel cell
Absorption cooling
Cogeneration
Trigeneration
Hotel energy management
Hong Kong
Publisher: Elsevier
Journal: Energy and buildings 
ISSN: 0378-7788
EISSN: 1872-6178
DOI: 10.1016/j.enbuild.2014.01.053
Rights: © 2014 Elsevier B.V. All rights reserved.
NOTICE: this is the author’s version of a work that was accepted for publication in Energy and Buildings. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Energy and Buildings, vol. 75 (June 2014), DOI: 10.1016/j.enbuild.2014.01.053
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
SOFC_Cogeneration_System_HK.pdfPre-published version952.38 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

295
Last Week
0
Last month
Citations as of Apr 21, 2024

Downloads

828
Citations as of Apr 21, 2024

SCOPUSTM   
Citations

49
Last Week
0
Last month
0
Citations as of Apr 26, 2024

WEB OF SCIENCETM
Citations

48
Last Week
1
Last month
2
Citations as of Apr 25, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.