Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/62513
PIRA download icon_1.1View/Download Full Text
DC FieldValueLanguage
dc.contributorDepartment of Building Services Engineering-
dc.creatorXu, XH-
dc.creatorWang, SW-
dc.date.accessioned2017-01-09T01:18:58Z-
dc.date.available2017-01-09T01:18:58Z-
dc.identifier.issn1002-8528-
dc.identifier.urihttp://hdl.handle.net/10397/62513-
dc.language.isozhen_US
dc.publisher中國學術期刊(光盤版)電子雜誌社en_US
dc.rights© 2007 中国学术期刊电子杂志出版社。本内容的使用仅限于教育、科研之目的。en_US
dc.rights© 2007 China Academic Journal Electronic Publishing House. It is to be used strictly for educational and research purposes.en_US
dc.subjectCentralized air-conditioning systemen_US
dc.subjectSeawater coolingen_US
dc.subjectPressure differential resettingen_US
dc.subjectAdaptive optimal controlen_US
dc.subjectEnergy efficiencyen_US
dc.titleAdaptive optimal control of seawater cooling system in centralized air-conditioning systemen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.spage76-
dc.identifier.epage79-
dc.identifier.volume23-
dc.identifier.issue2-
dc.identifier.doi10.13614/j.cnki.11-1962/tu.2007.02.017-
dcterms.abstract在淡水缺乏的香港地区,中央空调系统通常采用海水进行冷却。在能源日益紧张的今天,对空调系统进行优化控制是提高能源效率及节省能源的一个重要途径。本文针对中央空调海水冷却系统提出了根据海水冷却水压力设定值调整的微分自适应优化控制方法实现空调系统能耗最小化,然后进一步对该自适应控制方法进行了基于模拟环境的实验验证。结果表明该方法可以降低系统能耗,提高能源使用效率。-
dcterms.abstractSeawater is usually used to cool down condensers in centralized air-conditioning systems in Hong Kong where the fresh water is very scarce.Optimal control is among the means to improve energy efficiency in air-conditioning system.This paper presents an adaptive optimal control strategy to optimize the seawater pressure set-point of variable-speed seawater pumps aiming at minimal energy consumptions.This optimization is achieved by adjusting the pressure set-point according to the estimated derivative of the total power with respect to seawater pressure differential.This strategy is validated using simulations.The tests show that significant saving in the overall energy consumption of the chilling system can be achieved by properly resetting the pressure set-point only.-
dcterms.accessRightsopen accessen_US
dcterms.alternative中央空调海水冷却系统自适应优化控制-
dcterms.bibliographicCitation建筑科学 (Building science), Feb. 2007, v. 23, no. 2, p. 76-79-
dcterms.isPartOf建筑科学 (Building science)-
dcterms.issued2007-
dc.identifier.rosgroupidr30248-
dc.description.ros2006-2007 > Academic research: refereed > Publication in refereed journal-
dc.description.oaVersion of Recorden_US
dc.identifier.FolderNumberOA_IR/PIRAen_US
dc.description.pubStatusPublisheden_US
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
r30248.pdf154.52 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show simple item record

Page views

108
Last Week
1
Last month
Citations as of Apr 21, 2024

Downloads

165
Citations as of Apr 21, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.