Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/61614
PIRA download icon_1.1View/Download Full Text
Title: Measurement of corneal tangent modulus using ultrasound indentation
Authors: Wang, LK
Huang, YP 
Tian, L
Kee, CS 
Zheng, YP 
Issue Date: Sep-2016
Source: Ultrasonics, Sept. 2016, v. 71, p. 20-28
Abstract: Biomechanical properties are potential information for the diagnosis of corneal pathologies. An ultrasound indentation probe consisting of a load cell and a miniature ultrasound transducer as indenter was developed to detect the force-indentation relationship of the cornea. The key idea was to utilize the ultrasound transducer to compress the cornea and to ultrasonically measure the corneal deformation with the eyeball overall displacement compensated. Twelve corneal silicone phantoms were fabricated with different stiffness for the validation of measurement with reference to an extension test. In addition, fifteen fresh porcine eyes were measured by the developed system in vitro. The tangent moduli of the corneal phantoms calculated using the ultrasound indentation data agreed well with the results from the tensile test of the corresponding phantom strips (R2=0.96). The mean tangent moduli of the porcine corneas measured by the proposed method were 0.089 ± 0.026 MPa at intraocular pressure (IOP) of 15 mmHg and 0.220 ± 0.053 MPa at IOP of 30 mmHg, respectively. The coefficient of variation (CV) and intraclass correlation coefficient (ICC) of tangent modulus were 14.4% and 0.765 at 15 mmHg, and 8.6% and 0.870 at 30 mmHg, respectively. The preliminary study showed that ultrasound indentation could be applied to the measurement of corneal tangent modulus with good repeatability and improved measurement accuracy compared to conventional surface displacement-based measurement method. The ultrasound indentation can be a potential tool for the corneal biomechanical properties measurement in vivo.
Keywords: Corneal biomechanics
Corneal tangent modulus
Intraocular pressure
Ultrasound indentation
Publisher: Elsevier
Journal: Ultrasonics 
ISSN: 0041-624X
EISSN: 1874-9968
DOI: 10.1016/j.ultras.2016.05.011
Rights: © 2016 Elsevier B.V. All rights reserved.
© 2016. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
a0752-n02_ULT2016.pdfPre-Published version1.35 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Final Accepted Manuscript
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

148
Last Week
0
Last month
Citations as of Apr 21, 2024

Downloads

107
Citations as of Apr 21, 2024

SCOPUSTM   
Citations

9
Last Week
0
Last month
Citations as of Apr 19, 2024

WEB OF SCIENCETM
Citations

6
Last Week
0
Last month
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.