Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/61606
PIRA download icon_1.1View/Download Full Text
Title: Responsivity of the differential-intensity surface plasmon resonance instrument
Authors: Abayzeed, SA
Smith, RJ
Webb, KF
Somekh, MG 
See, CW
Issue Date: 2016
Source: Sensors and actuators. B, Chemical, 2016, v. 235, p. 627-635
Abstract: Surface plasmon resonance is used for the sensitive measurement of minute concentrations of bio-analytes and probing of electrochemical processes. Typical refractive index sensitivity, for the intensity approach, is around 10-6 refractive index units (RIUs). A better sensitivity has been suggested by developing a differential-intensity detection method. This method relies on the excitation of surface plasmons using a weakly focused beam with the average angle of incidence equal to the resonance angle, while the reflected light is detected using a bi-cell photodiode. The Bi-cell signal is processed by calculating the difference between its two units, normalized to their sum. This ratio estimates the shift in the resonance angle using a model that represents the resonance curve with a quadratic function. However, this model does not explain the effects of parameters such as the angular width of the excitation beam and the specifications of the sensing structure on the system's response. This paper presents a detailed evaluation of the responsivity using experimental and theoretical approaches, which can predict the effect of the different parameters, paving the way towards the investigation of a better sensitivity and the optimization of the system's design for different applications.
Keywords: Bi-cell surface plasmon resonance system
Biosensing
Chemical sensing
Surface plasmon resonance
Publisher: Elsevier
Journal: Sensors and actuators. B, Chemical 
ISSN: 0925-4005
EISSN: 1873-3077
DOI: 10.1016/j.snb.2016.05.117
Rights: © 2016 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
The following publication Abayzeed, S. A., Smith, R. J., Webb, K. F., Somekh, M. G., & See, C. W. (2016). Responsivity of the differential-intensity surface plasmon resonance instrument. Sensors and Actuators B: Chemical, 235, 627-635 is available at https://doi.org/10.1016/j.snb.2016.05.117
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Abayzeed_Responsivity_differential-intensity.pdf2.9 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

125
Last Week
1
Last month
4
Citations as of Apr 14, 2024

Downloads

97
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

16
Last Week
0
Last month
Citations as of Apr 12, 2024

WEB OF SCIENCETM
Citations

16
Last Week
0
Last month
Citations as of Apr 18, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.