Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/55459
PIRA download icon_1.1View/Download Full Text
Title: Effects of ankle arthrodesis on biomechanical performance of the entire foot
Authors: Wang, Y 
Li, Z
Wong, DWC 
Zhang, M 
Issue Date: 9-Jul-2015
Source: PLoS one, 29 July 2015, v. 10, no. 7, e0134340
Abstract: Background/Methodology Ankle arthrodesis is one popular surgical treatment for ankle arthritis, chronic instability, and degenerative deformity. However, complications such as foot pain, joint arthritis, and bone fracture may cause patients to suffer other problems. Understanding the internal biomechanics of the foot is critical for assessing the effectiveness of ankle arthrodesis and provides a baseline for the surgical plan. This study aimed to understand the biomechanical effects of ankle arthrodesis on the entire foot and ankle using finite element analyses. A three-dimensional finite element model of the foot and ankle, involving 28 bones, 103 ligaments, the plantar fascia, major muscle groups, and encapsulated soft tissue, was developed and validated. The biomechanical performances of a normal foot and a foot with ankle arthrodesis were compared at three gait instants, first-peak, mid-stance, and second-peak.
Principal Findings/Conclusions Changes in plantar pressure distribution, joint contact pressure and forces, von Mises stress on bone and foot deformation were predicted. Compared with those in the normal foot, the peak plantar pressure was increased and the center of pressure moved anteriorly in the foot with ankle arthrodesis. The talonavicular joint and joints of the first to third rays in the hind- And mid-foot bore the majority of the loading and sustained substantially increased loading after ankle arthrodesis. An average contact pressure of 2.14 MPa was predicted at the talonavicular joint after surgery and the maximum variation was shown to be 80% in joints of the first ray. The contact force and pressure of the subtalar joint decreased after surgery, indicating that arthritis at this joint was not necessarily a consequence of ankle arthrodesis but rather a progression of pre-existing degenerative changes. Von Mises stress in the second and third metatarsal bones at the second-peak instant increased to 52 MPa and 34 MPa, respectively, after surgery. These variations can provide indications for outcome assessment of ankle arthrodesis surgery.
Publisher: Public Library of Science
Journal: PLoS one 
EISSN: 1932-6203
DOI: 10.1371/journal.pone.0134340
Rights: © 2015 Wang et al. This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
The following publication: Wang Y, Li Z, Wong DW-C, Zhang M (2015) Effects of Ankle Arthrodesis on Biomechanical Performance of the Entire Foot. PLoS ONE 10(7): e0134340 is available at https://doi.org/10.1371/journal.pone.0134340
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Wang_Effects_ankle_arthrodesis.PDF5.74 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

126
Last Week
0
Last month
Citations as of May 5, 2024

Downloads

94
Citations as of May 5, 2024

SCOPUSTM   
Citations

54
Last Week
1
Last month
Citations as of Apr 4, 2024

WEB OF SCIENCETM
Citations

42
Last Week
0
Last month
Citations as of May 2, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.