Abstract: 3-D ultrasound (US) can significantly improve the visualization of musculoskeletal tissues, such as residual limbs, feet and hands. Traditionally, mechanical scanning is normally required to obtain the entire volume of these limb extremities. In this paper, a new scanning approach using a water bag was described to collect the complete volume of various tissues surrounding bones. The water bag was used to contain the limb extremity and the scanning was conducted on its external surface from different directions. The recorded 2-D US images containing complete anatomic information surrounding the bones from different directions were used to form full 3-D volumes of the limb extremities. A plastic auxiliary apparatus was designed to hold the water bag and support the subject’s limb part with an armrest. A corresponding algorithm was proposed to remove invalid image information within each sweep by a separating plane defined semiautomatically. Two phantoms were used to test the repeatability and accuracy of the imaging. The distance between two plastic bands attached to a plastic tube filled with US gel measured by a micrometer and from the four reconstructed volumes were 39.03 ± 0.36 mm and 39.2 ± 0.5 mm, respectively. The diameter, height and volume of a silicone cylinder phantom measured for the 10 reconstructed volumes were 40.2 ± 1.4 mm, 12.9 ± 1.0 mm and 16400 ± 1600 mm³, respectively. They agreed with the corresponding results obtained by the micrometer, which were 41.29 ± 0.13 mm, 12.98 ± 0.17 mm and 17370 ± 140 mm³, respectively. The reconstructed volumes of the two phantoms, a chicken leg in vitro, and human fingers in vivo were also reported. The preliminary results obtained in this study demonstrated that this new scanning approach should have potential for the 3-D US imaging of musculoskeletal extremities using freehand scanning.
URI: http://hdl.handle.net/10397/2333
ISSN: 0301-5629
DOI: 10.1016/j.ultrasmedbio.2005.01.007
Rights: Ultrasound in Medicine and Biology © 2005 World Federation for Ultrasound in Medicine & Biology. The journal web site is located at http://www.sciencedirect.com.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Huang QH et al UMB 2005 3D Ultrasound using Water Bag.pdfPre-published version1.99 MBAdobe PDFView/Open
Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

8
Last Week
0
Last month
0
Citations as of Jun 2, 2016

WEB OF SCIENCETM
Citations

6
Last Week
0
Last month
0
Citations as of Jul 30, 2016

Page view(s)

407
Last Week
1
Last month
Checked on Jul 24, 2016

Download(s)

220
Checked on Jul 24, 2016

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.