Title: Quasi-linear viscoelastic properties of fibrotic neck tissues obtained from ultrasound indentation tests in vivo
Authors: Huang, YP
Zheng, YP 
Leung, SF
Keywords: Radiation-induced fibrosis
Hand palpation
Ultrasound indentation
Soft tissue
Tissue mechanical properties
Tissue viscoelasticity
Issue Date: Feb-2005
Publisher: Elsevier
Source: Clinical biomechanics, Feb. 2005, v. 20, no. 2, p. 145-154 How to cite?
Journal: Clinical biomechanics 
Abstract: Background. Hand palpation is a conventional way to assess and document soft tissue fibrosis. But it is semi-quantitative and subjective, so there is a need to develop quantitative and objective methods for this purpose.
Methods. 105 patients with different degrees of radiation-induced fibrosis of soft tissue of the neck were assessed using an ultrasound indentation method. The force response was reconstructed from the indentation history using a quasi-linear viscoelastic model with four material parameters. The parameters which best curve-fitted the force response with respect to the experimentally measured one, were selected as the viscoelastic properties of the tested soft tissue. These parameters were compared among patient subgroups with different degrees of fibrosis as scored by hand palpation, and also compared with those of a control group of healthy, non-irradiated subjects. Their relation to the rotation range of the neck and the effective Young’s modulus, were also assessed.
Findings. Soft tissue with a more severe degree of fibrosis was associated with a larger initial stiffness and a more rapid increase in stiffness under loading. Viscoelasticity parameters could discriminate soft tissue with different degrees of clinical fibrosis and had significant correlation with clinical parameters of fibrosis.
Interpretation. Change of viscoelastic properties is reflection of pathological modifications of components in fibrotic soft tissues. Measurement of viscoelasticity parameters of soft tissue provides a quantitative and objective approach for the researcher and clinician to quantify soft tissue fibrosis.
URI: http://hdl.handle.net/10397/2331
ISSN: 0268-0033
DOI: 10.1016/j.clinbiomech.2004.09.012
Rights: Clinical Biomechanics © 2004 Elsevier. The journal web site is located at http://www.sciencedirect.com.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Huang et al Clinic Biomech 2005 Fibrosis QLV parameters.pdfPre-published version317 kBAdobe PDFView/Open
Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

21
Last Week
0
Last month
0
Citations as of May 1, 2016

WEB OF SCIENCETM
Citations

20
Last Week
0
Last month
0
Citations as of Apr 30, 2016

Page view(s)

315
Last Week
0
Last month
Checked on May 1, 2016

Download(s)

228
Checked on May 1, 2016

Google ScholarTM

Check

Altmetric



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.