Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/1977
DC FieldValueLanguage
dc.contributorDepartment of Health Technology and Informatics-
dc.creatorZheng, YP-
dc.creatorMak, AFT-
dc.creatorLue, B-
dc.date.accessioned2014-12-11T08:25:41Z-
dc.date.available2014-12-11T08:25:41Z-
dc.identifier.issn0748-7711-
dc.identifier.urihttp://hdl.handle.net/10397/1977-
dc.language.isoenen_US
dc.publisherU.S. Department of Veterans Affairs, Rehabilitation Research and Development Serviceen_US
dc.subjectCAD/CAMen_US
dc.subjectIndentation testen_US
dc.subjectProsthetics tissueen_US
dc.subjectBiomechanicsen_US
dc.subjectResidual limb assessmenten_US
dc.subjectSoft tissue biomechanicsen_US
dc.subjectTissue mechanicsen_US
dc.subjectUltrasound instrumentationen_US
dc.titleObjective assessment of limb tissue elasticity : development of a manual indentation procedureen_US
dc.typeJournal/Magazine Articleen_US
dc.description.otherinformationRehabilitation Engineering Centreen_US
dc.identifier.spage71-
dc.identifier.epage85-
dc.identifier.volume36-
dc.identifier.issue2-
dcterms.abstractAn ultrasound indentation system with a pen-size hand-held probe was developed and used to obtain the effective Young's moduli of forearm and lower limb soft tissues in 12 subjects. Since the probe is manually driven, the alignment of the probe and control of the rate of indentation are parameters upon which the results obtained depend. This paper addresses whether manual indentation tests with the probe are sufficiently acceptable and repeatable for objective biomechanical characterization of limb tissues. Forearms of three normal subjects were tested in two states of muscular contraction. Six different indentation rates, ranging from 0.75 mm/s to 7.5 mm/s, were imposed. The load-indentation responses obtained were shown to be well represented by quadratic functions. A linear elastic indentation solution was used to extract the effective Young's modulus. The material parameters extracted were repeatable and rather rate-insensitive for the range of rates used. The effective Young's modulus obtained was found to significantly increase as a result of contraction of the underlying muscles. Indentor misalignment experiments demonstrated that misalignment affects the measurement from which the effective Young's modulus of soft tissues is calculated. This effect, however, was found to decrease as the tissue thickness increased. With the investigation of the above issues, a procedure has been established for the extraction of effective Young's moduli of limb soft tissues from manual cyclic indentation responses. Tests on experimental subjects' lower limbs further demonstrated that the ultrasonic indentor is a feasible instrument for characterization of the biomechanical properties of limb soft tissues. Paired-t tests showed that the effective Young's moduli of the lower limb soft tissues of three elderly persons with transtibial amputation were significantly smaller than those of six unimpaired young subjects.-
dcterms.bibliographicCitationJournal of rehabilitation research and development, Apr. 1999, v. 36, no. 2, p. 71-85-
dcterms.isPartOfJournal of rehabilitation research and development-
dcterms.issued1999-04-
dc.identifier.isiWOS:000085584800003-
dc.identifier.scopus2-s2.0-0033108778-
dc.description.oapublished_final-
Appears in Collections:Journal/Magazine Article
Files in This Item:
File Description SizeFormat 
1999 J Rehab Res Dev - assessment of limb tissue elasticity.pdf1.02 MBAdobe PDFView/Open
Access
View full-text via PolyU eLinks SFX Query
Show simple item record
PIRA download icon_1.1View/Download Full Text

SCOPUSTM   
Citations

108
Last Week
0
Last month
Citations as of Feb 15, 2020

WEB OF SCIENCETM
Citations

90
Last Week
1
Last month
1
Citations as of Jul 11, 2020

Page view(s)

711
Last Week
4
Last month
Citations as of Jul 12, 2020

Download(s)

556
Citations as of Jul 12, 2020

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.