Title: Dynamic contour tonometry over silicone hydrogel contact lens
Authors: Lam, AKC 
Tse, JSH 
Issue Date: 2014
Source: Journal of optometry, 2014, v. 7, no. 2, p. 91-99
Abstract: Purpose This study compared the measurements of intraocular pressure (IOP) and ocular pulse amplitude (OPA) using the Dynamic Contour Tonometry (DCT) over silicone hydrogel contact lenses of different modulus. Corneal biomechanics were also measured using the Ocular Response Analyzer (ORA). Methods Forty-seven young (mean age 22.3 years, standard deviation 1.2 years) subjects had IOP, OPA, corneal hysteresis (CH) and corneal resistance factor (CRF) measured without lens and with two brands of silicone hydrogel contact lenses. Each eye wore one brand followed by another, randomly assigned, and then the lenses switched over. Difference and agreement of IOP and OPA with and without silicone hydrogel contact lens were studied. Results The right and left eyes had similar corneal curvatures, central corneal thicknesses, IOP, OPA and corneal biomechanics at baseline. No significant difference was found in CH and CRF when they were measured over different contact lenses. IOP demonstrated a greater difference (95% limits of agreement: 2.73 mmHg) compared with no lens when it was measured over high modulus silicone hydrogel lenses. Agreement improved over low lens modulus silicone hydrogel lenses (95% limits of agreement: 2.2-2.4 mmHg). 95% limits of agreement were within 1.0 mmHg for OPA. Conclusions This study demonstrated the feasibility of DCT over silicone hydrogel lenses. Low lens modulus silicone hydrogel contact lens in situ has no clinical effect on DCT.
Keywords: Corneal hysteresis
Corneal resistance factor
Intraocular pressure
Lens modulus
Ocular pulse amplitude
Publisher: Spanish Council of Optometry
Journal: Journal of Optometry 
ISSN: 1989-1342
DOI: 10.1016/j.optom.2013.07.005
Rights: © 2013 Spanish General Council of Optometry. Published by Elsevier España, S.L.
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
The following publication Lam, A. K., & Jimmy, S. H. (2014). Dynamic contour tonometry over silicone hydrogel contact lens. Journal of optometry, 7(2), 91-99 is available at https://doi.org/10.1016/j.optom.2013.07.005
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
Lam_Dynamic_Contour_Tonometry.pdf927.86 kBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Page views

114
Last Week
1
Last month
Citations as of Apr 14, 2024

Downloads

39
Citations as of Apr 14, 2024

SCOPUSTM   
Citations

6
Last Week
0
Last month
0
Citations as of Apr 5, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.