Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/117889
PIRA download icon_1.1View/Download Full Text
Title: Dosimetric investigation of multi-parametric 4D-MRI for radiotherapy in liver cancer
Authors: Li, S
Zhu, X
Xiao, H 
Liu, W
Zhang, Y
Cai, J 
Li, T 
Lu, Y
Issue Date: Dec-2025
Source: Radiation oncology, Dec. 2025, v. 20, no. 1, 51
Abstract: Background: In radiotherapy, inadequate management of organ motion in liver cancer may lead to inadequate delineation accuracy, resulting in the underdosage of target tissues and overdosage of surrounding normal tissues. To investigate the clinical potential of multi-parametric 4D-MRI in the target delineation and dose accuracy for liver cancer radiotherapy.
Methods: Twenty patients receiving radiotherapy for liver cancer were enrolled. Each patient underwent contrast-enhanced planning CT (free-breathing), contrast-enhanced T1-weighted (free-breathing), T2-weighted (gated) 3D-MRI, and low-quality 4D-MRI using the time resolved imaging with interleaved stochastic trajectories volumetric interpolated breath-hold examination (TWIST-VIBE) sequence. A dual-supervised deformation estimation model was used to generate a 4D deformable vector field (4D-DVF) from 4D-MRI data, and the prior images were deformed using this 4D-DVF to generate multi-parametric 4D-MRI. Assisted by 3D-MRI and multi-parametric 4D-MRI, target contours were performed on the planning CT, resulting in the generation of Target_3D and Target_4D. Clinical plans, Plan_3D and Plan_4D, were designed based on these contours respectively. To explore the dosimetric variations resulting from different contours without re-optimization, Plan_3D was directly applied to Target_4D, and Plan_4D was applied to Target_3D to generate Plan_3D’ and Plan_4D’ respectively. Target volume, contours, dose-volume histograms (DVHs), conformity index (CI), homogeneity index (HI), maximum and mean dose to organ as risks (OARs) were compared and evaluated.
Results: Mean volume differences between Target_3D and Target_4D were 2.76 cm3 (standard deviation [SD] 3.42 cm3) in the caudate lobe, 181.54 cm3 (SD 68.50 cm3) in the left hepatic lobe, and 26.08 cm3 (SD 20.52 cm3) in the right hepatic lobe. Mean and SD of CI and HI is 1.02 ± 0.04 and 0.108 ± 0.02 in Plan_3D, 1.02 ± 0.01 and 0.107 ± 0.01 in Plan_4D. There were no statistically significant differences in OAR doses between Plan_3D and Plan_3D’, between Plan_4D and Plan_4D’. However, a statistically significant difference in target dose was observed between Plan_3D and Plan_3D’ (P = 1.47 × 10⁻⁷) and between Plan_4D and Plan_4D’ (P = 0.013). Plan_3D’ meets 100% of the prescription dose covering mean 77.89% (SD 10.13%) of the Targeted_4D volume, while Plan_4D’ covered mean 94.17% (SD 3.12%) of the Targeted_3D volume.
Conclusions: 3D image-guided target delineation may be more likely to underestimate target volume and compromise dose coverage, suggesting that using multi-parametric 4D-MRI can provide more precise target contours and enhance target dose coverage.
Keywords: DDEM
Liver cancer
Multi-parametric 4D-MRI
Plan
Radiotherapy
Target contouring
Publisher: BioMed Central Ltd.
Journal: Radiation oncology 
EISSN: 1748-717X
DOI: 10.1186/s13014-025-02600-3
Rights: © The Author(s) 2025. Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
The following publication Li, S., Zhu, X., Xiao, H. et al. Dosimetric investigation of multi-parametric 4D-MRI for radiotherapy in liver cancer. Radiat Oncol 20, 51 (2025) is available at https://doi.org/10.1186/s13014-025-02600-3.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
s13014-025-02600-3.pdf2.09 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.