Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/117864
PIRA download icon_1.1View/Download Full Text
Title: SMNS structure based fiber optic interferometer for cadmium detection
Authors: Wang, X 
Al, Noman, A
Liu, Y 
Yu, C 
Issue Date: 10-Apr-2025
Source: Optics Express, 10 Mar. 2025, v. 33, no. 8, p. 17233-17244
Abstract: A cost-effective, easy-to-manufacture, compact, and reliable single-mode fiber/ multimode fiber/ no-core fiber/ single-mode fiber (SMNS) structure based interferometer is proposed for the detection of cadmium ions (Cd2+). This setup involves splicing a segment of multimode fiber (MMF) and no-core fiber (NCF) between a single-mode fiber (SMF), followed by a functionalization procedure with a composite of graphene oxide (GO)-cysteamine (MEA) and chitosan (CS)-Cd2+ imprinted polymer (Cd2+IP). The sensitivity of the sensors has been calculated by monitoring the interference minima. Three identical probes have been fabricated to ensure the duplicability and the highest sensing sensitivity is measured at -0.1211 nm/ parts per billion (ppb) in the cadmium detection range of 0 ppb to 10 ppb with a response time of 90 s. The probe demonstrates a high selectivity for Cd2+ compared to other heavy metal ions. The response of the probe in various pH solutions has been investigated to minimize the sensing error. Further, the temperature crosstalk is eliminated by assessing the response of a fiber Bragg grating (FBG).
Publisher: Optica
Journal: Optics express 
ISSN: 2156-7085
EISSN: 1094-4087
DOI: 10.1364/OE.547717
Rights: © 2025 Optica Publishing Group under the terms of the Open Access Publishing Agreement. Users may use, reuse, and build upon the article, or use the article for text or data mining, so long as such uses are for non-commercial purposes and appropriate attribution is maintained. All other rights are reserved.
The following publication Wang, X., Noman, A. A., Liu, Y., & Yu, C. (2025). SMNS structure based fiber optic interferometer for cadmium detection. Optics Express, 33(8), 17233–17244 is available at https://doi.org/10.1364/OE.547717.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
oe-33-8-17233.pdf4.24 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.