Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/117787
PIRA download icon_1.1View/Download Full Text
Title: Performance of single and built-up I-shaped cold formed steel stud under double sided walls fire exposure
Authors: Hassoune, M
Kada, A
Menadi, B
Lamri, B
Yessad, O
Piloto, PAG
Jiang, L 
Issue Date: 15-Jul-2025
Source: Engineering structures, 15 July 2025, v. 335, 120392
Abstract: Light-gauge Steel Frame (LSF) walls are expanded nowadays due to several advantages, especially to achieve economy, sustainability and improved structural performance. The latter has stimulated designers to adopt Cold Formed Steel (CFS) members as primary components of LSF walls. However, the high thermal conductivity and slenderness of CFS sections make them vulnerable to mechanical degradation during fire. While numerous studies have investigated the performance of CFS stud walls under one-sided fire exposure, the investigation on double-sided fire exposure remains limited, especially for built-up studs. This study investigates the performance of CFS stud walls under compression loading, subjected to one-sided and double-sided fire exposure. Numerical models were developed using ANSYS APDL, considering geometric imperfections, material nonlinearities and contact element effect. The developed models were validated against previous experimental and numerical results. Various parameters were analysed through parametric study, including steel thickness and grades, web stiffeners and I-shaped stud configurations. The results demonstrate the significant impact of the double-sided fire exposure on CFS walls performance, reducing the fire resistance by 41 % and 50 % for CFS thicknesses of 1.15 mm and 1.5 mm, respectively, compared to one-sided fire exposure. Steel grade and I-shaped configurations were found to significantly enhance the load-bearing capacity and fire resistance of CFS walls. The maximum temperatures predicted for each load ratio were used to calculate the load ratio as per EN1993–1–2. New formulas, based on load ratio were proposed to predict the maximum temperature at failure for CFS walls subjected to one-sided and double-sided fire exposure. The findings will improve fire structural design codes of CFS walls, by ensuring accurate predictions of limiting temperatures and fire resistance and providing engineers with substantial data for LSF structures.
Keywords: Built-up I-shaped
Cold formed steel (CFS)
Fire resistance
Light gauge steel frame (LSF) walls
Numerical modelling
Web stiffeners
Publisher: Elsevier Ltd
Journal: Engineering structures 
ISSN: 0141-0296
EISSN: 1873-7323
DOI: 10.1016/j.engstruct.2025.120392
Rights: © 2025 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license ( http://creativecommons.org/licenses/by-nc-nd/4.0/ ).
The following publication Hassoune, M., Kada, A., Menadi, B., Lamri, B., Yessad, O., Piloto, P. A. G., & Jiang, L. (2025). Performance of single and built-up I-shaped cold formed steel stud under double sided walls fire exposure. Engineering Structures, 335, 120392 is available at https://doi.org/10.1016/j.engstruct.2025.120392.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
1-s2.0-S0141029625007837-main.pdf16.76 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.