Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/117589
PIRA download icon_1.1View/Download Full Text
Title: Lightning flashover characteristic and effective protection measures of 10 kV distribution line network
Authors: Zhang, S
Xiao, X
Jia, L
Chen, H
Qu, L
Yeung, C 
Ding, Y 
Du, Y 
Issue Date: Oct-2025
Source: Energies, Oct. 2025, v. 18, no 19, 5097
Abstract: Among various failure causes, lightning overvoltage represents the most significant threat to overhead distribution lines, which serve as critical components in power systems. This study uses the hybrid partial element equivalent circuit (PEEC) multi-conductor transmission line (MTL) method to perform overvoltage simulations and investigate lightning risk distribution along distribution lines developed from a real 10 kV distribution networks in Guizhou, China. The results of the rocket-triggered lightning observation verify the accuracy of the hybrid method for direct lightning simulation. Combining the Monte Carlo method with the electro-geometric model (EGM), the impact of differential protection configurations on annual lightning flashover rates is analyzed. The results demonstrate that lightning strikes on phase wires generate high-magnitude overvoltages but with limited spatial influence, resulting in fewer pole flashovers. Conversely, strikes on poles produce lower overvoltage peaks but affect wider areas, leading to significantly more flashovers. Using annual flashover rates as the risk evaluation metric, the line topologies into high-risk, medium-risk, and other low-risk areas are classified. Targeting an annual flashover rate below 0.4 as the design objective, the configuration schemes of the arresters are progressively optimized. This risk-based approach provides an effective reference framework for differential protection design of distribution line safeguards.
Keywords: Arresters
Differentiated protection
Direct lightning
Distribution lines
EGM
Monte Carlo
Risk distribution
Publisher: MDPI AG
Journal: Energies 
EISSN: 1996-1073
DOI: 10.3390/en18195097
Rights: Copyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
The following publication Zhang, S., Xiao, X., Jia, L., Chen, H., Qu, L., Yeung, C., Ding, Y., & Du, Y. (2025). Lightning Flashover Characteristic and Effective Protection Measures of 10 kV Distribution Line Network. Energies, 18(19), 5097 is available at https://doi.org/10.3390/en18195097.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
energies-18-05097.pdf5.05 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record