Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/11527
Title: Experience of using a chilled water circuit design to expedite in situ chiller performance measurement
Authors: Yik, FWH
Lee, SH
Lai, JHK 
Chan, KT 
Issue Date: 2010
Publisher: SAGE Publications
Source: Building services engineering research and technology, 2010, v. 31, no. 3, p. 279-300 How to cite?
Journal: Building services engineering research and technology 
Abstract: A chilled water circuit design that can facilitate expeditious in situ chiller performance measurement has been adopted in a chiller plant and its effectiveness has been demonstrated. Before chiller tests commenced, the measurement accuracies of the sensors in the plant were checked by simple measurements and an analysis of the plant operation records. The analysis unveiled that the chilled water flow rate through the chillers was lower than the design flow rate and the chilled water return temperature often stayed below the design level due to excessive flow rate demand, which would hinder full load tests on the chillers. After the causes of the problems were diagnosed and the problems resolved as far as possible, measurement of the full- and part-load performance of the newly installed chillers was successfully conducted. This work demonstrated that the chilled water circuit design is effective in facilitating expeditious in situ chiller performance measurement but its use requires a properly functioning chilled water system. Practical applications: As the results presented in the paper show, the proposed chilled water circuit design is effective in reducing the time and effort required for measurement and verification of the full- and part-load performance of water chillers. This, in turn, allows more frequent chiller performance measurements to be made for detecting system or sensor faults and deterioration in chiller performance, which would help upkeep chiller energy efficiency and reliability. Described in the paper includes also several practical methods for verification of sensor accuracy and some common problems with chilled water systems where fan-coil units with on/off control are adopted.
URI: http://hdl.handle.net/10397/11527
ISSN: 0143-6244
EISSN: 1477-0849
DOI: 10.1177/0143624410370171
Appears in Collections:Journal/Magazine Article

Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

1
Last Week
0
Last month
0
Citations as of Oct 9, 2018

Page view(s)

55
Last Week
0
Last month
Citations as of Oct 15, 2018

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.