Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/115009
PIRA download icon_1.1View/Download Full Text
Title: An ICU-grade breathable cardiac electronic skin for health, diagnostics, and intraoperative and postoperative monitoring
Authors: Zhuang, QA 
Yao, KM
Song, X 
Zhang, Q
Zhang, C 
Wang, HM 
Yang, RF 
Zhao, GY
Li, SH
Shu, HH
Huang, QY 
Chai, YF
Yu, XE
Zheng, ZJ 
Issue Date: 2025
Source: Science advances, 2025, v. 11, no. 12, eadu3146
Abstract: Cardiovascular digital health technologies potentially outperform traditional clinical equipment through their noninvasive, on-body, and portable monitoring with mass cardiac data beyond the confines of inpatient settings. However, existing cardiovascular wearables have difficulty with providing medical-grade accuracy with a chronically comfortable and stable patient/consumer device interface for reliable clinical decision-making. Here, we develop an intensive care unit (ICU)-grade breathable cardiac electronic skin system (BreaCARES) for real-time, wireless, continuous, and comfortable cardiac care. BreaCARES enables a novel digital cardiac care platform for health care, outpatient diagnostics, stable intraoperative monitoring during heart surgery, and continuous and comfortable inpatient postoperative cardiac care, exhibiting ICU-grade accuracy while having superior anti-interference stability, portability, and long-term on-skin biocompatibility to the clinically and commercially available cardiac monitors in cardiovascular ICUs.
Publisher: American Association for the Advancement of Science (AAAS)
Journal: Science advances 
EISSN: 2375-2548
DOI: 10.1126/sciadv.adu3146
Rights: Copyright © 2025 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works. Distributed under a Creative Commons Attribution NonCommercial License 4.0 (CC BY-NC).
Creative Commons Attribution-NonCommercial 4.0 International (https://creativecommons.org/licenses/by-nc/4.0/)
The following publication Qiuna Zhuang et al. ,An ICU-grade breathable cardiac electronic skin for health, diagnostics, and intraoperative and postoperative monitoring.Sci. Adv.11,eadu3146(2025) is available at https://dx.doi.org/10.1126/sciadv.adu3146.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
sciadv.adu3146.pdf5.46 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

WEB OF SCIENCETM
Citations

10
Citations as of Dec 18, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.