Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/113057
PIRA download icon_1.1View/Download Full Text
Title: Performance evaluation of a recirculated personalized air curtain combined with displacement ventilation in mitigating indoor airborne transmission
Authors: Xu, J 
Zhai, H 
So, LK 
Wang, C 
Guo, H 
Issue Date: 15-Aug-2025
Source: Journal of hazardous materials, 15 Aug. 2025, v. 494, 138446
Abstract: To mitigate the risk of airborne transmission, we explored the integration of a recirculated personalized air curtain (rPAC) with displacement ventilation (DV) using computational fluid dynamics (CFD) simulations. The rPAC can utilize indoor air directly, drawing clean air from the lower room space supplied by the DV system. Our study assessed the effectiveness of the rPAC in reducing the intake fraction of expiratory droplets from transient coughing and steady speaking indoors. We categorized droplets into small (initial diameter ≤20 μm), medium (50 μm), and large (100 μm) sizes. Large droplets from both activities generally had negligible intake fractions. The rPAC effectively reduced the intake fraction from coughing and speaking, although its performance varied with respiratory activities and exhalation directions. At 0° and 30°, the rPAC reduced the intake fraction of small coughing droplets by over 90 % and medium droplets by 74 %-98 %, with significant reductions also observed for speaking. However, at 60°, the rPAC increased the intake fraction of medium coughing droplets and small droplets from speaking due to complex airflow-droplet interaction dynamics. This study highlights the potential of rPAC as an effective control measure to improve indoor air quality and mitigate respiratory disease transmission, though its effectiveness is influenced by exhalation direction and droplet size.
Keywords: Airborne transmission
Exposure
Protection
Recirculated personalized air curtain
Respiratory diseases
Publisher: Elsevier
Journal: Journal of hazardous materials 
ISSN: 0304-3894
EISSN: 1873-3336
DOI: 10.1016/j.jhazmat.2025.138446
Rights: © 2025 The Author(s). Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
The following publication Xu, J., Zhai, H., So, L. K., Wang, C., & Guo, H. (2025). Performance Evaluation of a Recirculated Personalized Air Curtain Combined with Displacement Ventilation in Mitigating Indoor Airborne Transmission. Journal of Hazardous Materials, 494, 138446 is available at https://doi.org/10.1016/j.jhazmat.2025.138446.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
1-s2.0-S0304389425013615-main.pdf17.04 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

SCOPUSTM   
Citations

3
Citations as of Dec 19, 2025

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.