Please use this identifier to cite or link to this item: http://hdl.handle.net/10397/112721
PIRA download icon_1.1View/Download Full Text
Title: Characterization of LIPUS parameters suitable for hip bone fracture
Authors: Palanisamy, P 
Li, S 
Shea, QTK 
Li, MMC
Cheung, WH
Qin, L
Chow, SKH
Zheng, YP 
Issue Date: Apr-2025
Source: Ultrasound in medicine and biology, Apr. 2025, v. 51, no. 4, p. 695-706
Abstract: Objective: To investigate the effects of ultrasound treatment on the healing of hip bone fractures using frequencies of 0.5 MHz and 1.5 MHz with constant intensity (30 mW/cm2) at the fractured site.
Methods: For the ex vivo experiments, acoustic attenuations of 0.5 MHz and 1.5 MHz ultrasound were measured and compared using different thicknesses of human cadaver and porcine tissues in a hydrophone system. For the in vivo experiments, 20 hip-fractured rabbits were divided into four groups, namely: control, 1.5 MHz with unchangeable intensity (positive control), 0.5 MHz with changeable intensity, and 1.5 MHz with changeable intensity. For the 0.5 and 1.5 MHz groups with changeable intensity, a constant intensity of 30 mW/cm2 at the fracture site was achieved using a compensation method for power transmission with reference to the acoustic attenuation.
Results: The effective intensity measured using a hydrophone was substantially reduced to 6.16 mW/cm2 from 30 mW/cm2 in the positive control device after propagating soft tissues with a thickness of 5.0 cm, with an attenuation of approximately 6.0 dB. Meanwhile, for the 0.5 and 1.5 MHz groups, the ultrasound intensity was consistently controlled at 30 mW/cm2 after passing through tissues with different thicknesses using the compensation method. In the in vivo study using a newly established hip fracture rabbit model, the best results in bone histomorphometry, mechanical properties, and histological evaluation were consistently found in the 0.5 MHz group, while the 1.5 MHz group exhibited relatively better bone healing than the positive control group.
Conclusion: The results suggest a LIPUS frequency of 0.5 MHz together with the consistent intensity of 30 mW/cm2 at the fracture site for more effective treatment of hip bone fractures.
Keywords: Animal study
Hip bone fractures
Low-intensity pulsed ultrasound stimulation (LIPUS)
Optimal parameters
Publisher: Elsevier Inc.
Journal: Ultrasound in medicine and biology 
ISSN: 0301-5629
EISSN: 1879-291X
DOI: 10.1016/j.ultrasmedbio.2025.01.001
Rights: © 2025 The Author(s). Published by Elsevier Inc. on behalf of World Federation for Ultrasound in Medicine & Biology. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
The following publication Palanisamy, P., Li, S., Shea, Q. T.-K., Li, M. M.-C., Cheung, W.-H., Qin, L., Chow, S. K.-H., & Zheng, Y.-P. (2025). Characterization of LIPUS Parameters Suitable for Hip Bone Fracture. Ultrasound in Medicine & Biology, 51(4), 695-706 is available at https://doi.org/10.1016/j.ultrasmedbio.2025.01.001.
Appears in Collections:Journal/Magazine Article

Files in This Item:
File Description SizeFormat 
1-s2.0-S0301562925000018-main.pdf4.32 MBAdobe PDFView/Open
Open Access Information
Status open access
File Version Version of Record
Access
View full-text via PolyU eLinks SFX Query
Show full item record

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.